The resolution limits of the measured data are not changed but your output
file must contain all possible h k l even if there is no observations for
the lowest resolution ones..

dont worry about it!

Eleanor

On 26 July 2017 at 08:36, Andrew Marshall <andrew.c.marsh...@adelaide.edu.au
> wrote:

> Dear crystallographers,
>
> I have two datasets that were merged/scaled using ccp4's aimless, with
> resolution ranges of 52-1.7 and 57-1.9. However, upon refinement, the
> resolution range used by phenix.refine is 36-1.7 for one and 104-1.9 for
> the other. 1) Why does phenix.refine change the low resolution limits of my
> processed data? 2) How can I prevent this?
>
> Thanks,
>
> Andrew
>

Reply via email to