Tom Hammond
Tue, 6 Nov 2007 08:52:01 -0800
WB:We're discussing it here right now... what would the 'damages' be if a supply (ANY supply) could/would fail placing 24VDC at up to 30A on the K3's DC line?
I'm thinking about designing an external plug-in OVP kit. Unless YOU want to do it.
T At 10:45 11/06/2007, wayne burdick wrote:
A local discussion has 'erupted' regarding switching poser supplies and whetherthey can fail in an UNregulated (e.g. high) output voltage condition, or if when they fail will they (almost) always fail in a NO OUTPUT mode?I've never seen this happen myself, but I just added a task to my firmware list to turn the K3 off automatically if there's a persistent overvoltage condition (say, > 17 V for several seconds).73, Wayne N6KR --- http://www.elecraft.com
_______________________________________________ Elecraft mailing list Post to: Elecraft@mailman.qth.net You must be a subscriber to post to the list. Subscriber Info (Addr. Change, sub, unsub etc.):http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/subscribers.htm Elecraft web page: http://www.elecraft.com