Hmmm - sounds like its seen 868 read/write errors. However to advise you
better we need to see the output. I suspect it is huge because there are
error details for each of the 868 errors. How about post the first 200
lines of the smartctl output to the list?

Here are the first 91 lines.  After that it looks like error
specifics.  Please let me know what you think or if you need more
info.

smartctl version 5.36 [i686-pc-linux-gnu] Copyright (C) 2002-6 Bruce Allen
Home page is http://smartmontools.sourceforge.net/

=== START OF INFORMATION SECTION ===
Model Family:     Fujitsu MHT2xxxAT/MHU2100AT series
Device Model:     FUJITSU MHT2040AT
Serial Number:    NN50T481446T
Firmware Version: 0022
User Capacity:    40,007,761,920 bytes
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   6
ATA Standard is:  ATA/ATAPI-6 T13 1410D revision 3a
Local Time is:    Sat Jan 27 15:47:38 2007 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                       was never started.
                                       Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                       without error or no self-test has ever
                                       been run.
Total time to complete Offline
data collection:                 ( 293) seconds.
Offline data collection
capabilities:                    (0x7b) SMART execute Offline immediate.
                                       Auto Offline data collection
on/off support.
                                       Suspend Offline collection upon new
                                       command.
                                       Offline surface scan supported.
                                       Self-test supported.
                                       Conveyance Self-test supported.
                                       Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                       power-saving mode.
                                       Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                       No General Purpose Logging support.
Short self-test routine
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        (  40) minutes.
Conveyance self-test routine
recommended polling time:        (   2) minutes.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE
UPDATED  WHEN_FAILED RAW_VALUE
 1 Raw_Read_Error_Rate     0x000f   100   093   046    Pre-fail
Always       -       169149
 2 Throughput_Performance  0x0005   100   100   030    Pre-fail
Offline      -       15663104
 3 Spin_Up_Time            0x0003   100   100   025    Pre-fail
Always       -       0
 4 Start_Stop_Count        0x0032   099   099   000    Old_age
Always       -       1012
 5 Reallocated_Sector_Ct   0x0033   100   100   024    Pre-fail
Always       -       8559870279687
 7 Seek_Error_Rate         0x000f   100   100   047    Pre-fail
Always       -       3006
 8 Seek_Time_Performance   0x0005   100   100   019    Pre-fail
Offline      -       0
 9 Power_On_Seconds        0x0032   075   075   000    Old_age
Always       -       12656h+03m+48s
10 Spin_Retry_Count        0x0013   100   100   020    Pre-fail
Always       -       0
12 Power_Cycle_Count       0x0032   100   100   000    Old_age
Always       -       926
192 Power-Off_Retract_Count 0x0032   100   100   000    Old_age
Always       -       103
193 Load_Cycle_Count        0x0032   066   066   000    Old_age
Always       -       340716
194 Temperature_Celsius     0x0022   100   070   000    Old_age
Always       -       43 (Lifetime Min/Max 13/66)
195 Hardware_ECC_Recovered  0x001a   100   100   000    Old_age
Always       -       4244
196 Reallocated_Event_Count 0x0032   100   100   000    Old_age
Always       -       124838871047
197 Current_Pending_Sector  0x0012   091   091   000    Old_age
Always       -       10
198 Offline_Uncorrectable   0x0010   092   092   000    Old_age
Offline      -       16
199 UDMA_CRC_Error_Count    0x003e   200   196   000    Old_age
Always       -       143
200 Multi_Zone_Error_Rate   0x000f   100   100   060    Pre-fail
Always       -       28028
203 Run_Out_Cancel          0x0002   100   100   000    Old_age
Always       -       433780032038
SMART Error Log Version: 1
ATA Error Count: 868 (device log contains only the most recent five errors)
       CR = Command Register [HEX]
       FR = Features Register [HEX]
       SC = Sector Count Register [HEX]
       SN = Sector Number Register [HEX]
       CL = Cylinder Low Register [HEX]
       CH = Cylinder High Register [HEX]
       DH = Device/Head Register [HEX]
       DC = Device Command Register [HEX]
       ER = Error register [HEX]
       ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 868 occurred at disk power-on lifetime: 12653 hours (527 days + 5 hours)
 When the command that caused the error occurred, the device was
active or idle.

- Grant
--
gentoo-user@gentoo.org mailing list

Reply via email to