RE: Powder diffraction and Fuji image plate

Skage Reidar Hem
Mon, 22 Feb 2010 04:24:47 -0800

Dear Natale,

 

At Laurentian University we used exactly this technology at the Central 
Analytical Facility- we cut slices of the image plates to fit the Gandolfi 
camera - it worked well (with some hassle). I believe Andy McDonald (he is at 
the Dept. of Geology) is still using it. 

 

I'm not working with it any longer and I don't know how the technology evolved 
since 2006 - but I believe we used the BAS-1800 as well.

 

Best regards

 

Skage Reidar Hem

Project Manager

Ph.D., M.Sc.

 

Direct phone +45 3618 3754 · Mobile +45 3093 3754 · Fax: +45 3618 2799

s...@flsmidth.com

 

 

 

 

Laboratory Systems, Projects Execution

FLSmidth A/S

Høffdingsvej 34 · 2500 Valby · Denmark · Tel +45 36182700 · Fax +45 36182799

www.flsmidth.com/automation · DK reg.no. 15 02 88 82

 



 

 

 

 

 

This communication constitutes an electronic communication within the meaning 
of the Electronic Communications. Privacy Act, 18 USC 2510, and its disclosure 
is strictly limited to the recipient intended by the sender of this message. 
This communication may contain confidential and privileged material for the 
sole use of the intended recipient and receipt by anyone other than the 
intended recipient does not constitute a loss of the confidential or privileged 
nature of the communication. Any review or distribution by others is strictly 
prohibited. If you are not the intended recipient please contact the sender by 
return electronic mail and delete all copies of this communication.

 

________________________________

From: Natale Perchiazzi [mailto:nprietv...@yahoo.it] 
Sent: 22. februar 2010 12:57
To: lista rietveld
Subject: Powder diffraction and Fuji image plate

 

Dear All,

we are going to purchase a Fuji image plate system (Fuji BAS-1800) for our 
X-ray lab. I am planning to use these plates for powder diffraction, to be 
performed on small (<0.1mm) mineral fragments; the device to be used is still 
to be assembled. A possible choice could be to use a collimator, a Gandolfi 
camera basement for the crystal motion, the diffraction effects being then 
recorded in flat-plane geometry by the Fuji plate. Another choice would be to 
put the flat plane plate on a 4-circle diffractometer. There are several 
important details to be considered, and I wonder what to do to optimize the 
device, provided that we will have a budget of some Keuro to purchase the 
various components of the device.  I will be happy to hear your advices and to 
give more informations to anyone interested.

best regards       Natale Perchiazzi



 