Re: [pmacct-discussion] sfacctd and tagging with filters

2017-04-06 Thread Aurelien Kempiak
Yes, it's VLAN-tagged. I've tested your suggestion, it works !! Was I able to find this info myself (I can't find it in the documentation), or was it quite difficult to find it without asking here ? I'm asking this in order to improve my autonomy. Thanks a lot Paolo ! Le 06/04/2017 à

Re: [pmacct-discussion] sfacctd and tagging with filters

2017-04-06 Thread Paolo Lucente
Hi Aurelien, Is it possible your traffic is VLAN-tagged and/or MPLS-labelled? That may explain why tagging is not working, pcap filters are sensible to that. See for example here: https://www.mail-archive.com/pmacct-discussion@pmacct.net/msg02784.html Paolo On Tue, Apr 04, 2017 at 04:32:13PM

[pmacct-discussion] sfacctd and tagging with filters

2017-04-04 Thread Aurelien Kempiak
Hello there! I'm trying to tag my flows per set of hosts (each set is a customer) and record them into mysql. So, here is my (testing) pretag.map file : set_tag=101 ip=185.151.188.33 filter='src host 185.151.188.30' set_tag=102 ip=185.151.188.34 filter='src host 185.151.188.30' set_tag=103