On 04/06/2016 19:06, Remko Tronçon wrote:
When s6-svscan is running in a terminal, and I hit Ctrl-C, the processes
managed by s6 are not interrupted, and remain running after s6-svscan has
quit. I'm guessing this has something to do with CTRL-C behavior wrt
process groups, but I'm not knowledgeable enough on the subject to know
what's going on.

Is there a way to run s6-svscan from a terminal, and have CTRL-C do what
you would expect (i.e. the same as s6-svscanctl -i)?

 Add a "nosetsid" file to your service directories. That ensures that the
supervised processes are started in the same session as s6-svscan, so they
also receive a SIGINT on a ^C.

 This is not the default because running services in their own session is
the normal correct behaviour, and s6-svscan has no business running in a
terminal except for debugging purposes. So make sure you know what you are
doing. ;)

--