Pascal Thubert (pthubert) <[email protected]> wrote:
    >> > OTOH, there is one (or more?) RPL instance that is used for 6TiSCH
    >> > timing. I think all we need in 6top is an information of which RPL
    >> > instance(s) is (are) used for timing and hten the admin can read the
    >> > RPL info about that instance in the RPL data model.

    > There may be multiple instances, and one at least is used for ensuring
    > a loopless structure for time sync. 6top exposes its rank in that
    > instance in the beacons, so that's something we can expose in our data
    > model as well since we understand its abstract semantics. But apart
    > from that rank and the instance ID that is used for clock sync, all the
    > RPL info should be coming from the RPL data model, else it is
    > duplicated which looks like a bad idea as well as a layer violation.

okay, fair enough.
I will consider spinning up a YANG model for RPL info.

--
Michael Richardson <[email protected]>, Sandelman Software Works
 -= IPv6 IoT consulting =-