Hi!

Probably I miss something obvious here, but I just stumbled about two things
in RFC7554 and Minimal that seem to be contradicting at a first glance:
RFC7554 in A8 states: "Nodes can keep synchronization exclusively by
exchanging EBs." However, draft-ietf-6tisch-minimal-14 in section 6 states:
"EBs MUST NOT be used for time synchronization."

Can anyone enlighten me how to interpret this? May EBs be used for time
synchronization or not?

Cheers,
Oleg