On 11/12/2007, [EMAIL PROTECTED] <[EMAIL PROTECTED]> wrote:
> >> This looks like a hardware error (your disk is failing),
> >> not a software error (pull broke something).
> I think you want to start at a lower level than the fossil
> console. A recent thread, 'venti wrarena i/o errors,'
> discussed troubleshooting hardware disk errors, esp. with
> dd(1). Manufacturer disk setup/diagnosis tools can be
> helpful, too.

Thanks Josh,

The disk is indeed old, I already did a low level format, or that it's what
the tools I used told me :)

The problem was corrected after I booted with the plan9 livecd
and did a check to the disk with this.

fossil/fossil -c 'srv -p fscons'
con /srv/fscons
prompt: srv -AWP replica
prompt: fsys main config /dev/sdC0/fossil
prompt: fsys main open -AWP
warning: connecting to venti: cs: can't translate address: '/srv/dns' file
does not exist
prompt: fsys main
main: check fix

PS: Newbie self note. Don't do this without the livecd (on the running
file system).