Hi Jimmy,

This bug has been fixed and is in the new all-in-one installer which you'll 
hopefully find on the accessgrid.org website before you read this email.

Alternatively, the new Windows AG HD node services can be downloaded from:
  http://www.vislab.uq.edu.au/ag3/windows/NodeServices/


Doug

From: ag-tech-boun...@lists.mcs.anl.gov 
[mailto:ag-tech-boun...@lists.mcs.anl.gov] On Behalf Of Jimmy Miklavcic
Sent: Monday, 31 January 2011 7:11 AM
To: ag-t...@lists.mcs.anl.gov
Subject: Re: [AG-TECH] Black Magic Intensity Pro,Panasonic AG-HMC150 & AGtk 3.2

Here's the full error log that I get. I did notice that this error log 
immediately replaces another window so I have no record of the first error that 
is displayed (that I know of). Any help will be appreciated.


invalid command name ""

invalid command name ""

    while executing

"$cmd [expr round([$qscale get])]"

    invoked from within

"$qscale instate {!disabled} {

                  set cmd [$qscale cget -command]

                  $cmd [expr round([$qscale get])]

            }"

    (procedure "init_grabber" line 59)

    invoked from within

"init_grabber $V(grabber)"

    invoked from within

"if ![have grabber] {

            set DA [$videoDevice attributes]

            set DF [attribute_class $DA format]

            set DS [attribute_class $DA size]



            # first, see if d..."

    (procedure "transmit" line 3)

    invoked from within

"transmit"

    ("after" script)


Thanks,
Jimmy

From: ag-tech-boun...@lists.mcs.anl.gov 
[mailto:ag-tech-boun...@lists.mcs.anl.gov] On Behalf Of Jimmy Miklavcic
Sent: Saturday, January 29, 2011 6:38 PM
To: ag-t...@lists.mcs.anl.gov
Subject: [AG-TECH] Black Magic Intensity Pro, Panasonic AG-HMC150 & AGtk 3.2

I have a Blackmagic Intensity Pro HDMI Card, in a system with Windows XP and a 
Panasonic AGHMC150 camera. I've install Blackmagic drivers 7.94. When I set the 
cameras to 720/30p I get black, when I set the camera to 1080/60i I get nothing 
at all. I have set the service parameters in the node configuration to match 
the cameras output but no video.

I have this same configuration on two similar systems. On one, I get the 
application error when vic starts up that states - invalid command """". On the 
other system I don't see that error.

Does anyone have any insight into what might be going on?

Thanks,
Jimmy

Jimmy Miklavcic
Multimedia Specialist
University of Utah CHPC
155 S 1452 E RM 405
Salt Lake City, UT 84112
801-585-9335

Reply via email to