Hi Antonio, We're seeing the second problem (adding a new service when using unicast causes old ones to restart on a multicast address) here at RIT, running Windows XP. I just submitted a bug report for it ( http://bugzilla.mcs.anl.gov/accessgrid/show_bug.cgi?id=1678).
--Andrew Ford On 7/12/07, Antonio Bandeira < bande...@fe.up.pt<mailto:bande...@fe.up.pt>> wrote: Hi, I've found a few "problems" with the new AG3.1 beta. Don't know if it is just me, but... I am currently running FC7, but I think some of this problems can also be found in WinXP. - Bridge sorting is not persistent. After restart agtk the order is no longer the one set under "preferences". - Working in unicast mode, adding a new service under "node management" will cause all previously added services to restart using a multicast address. - Autoplace from VIC will not show up for the second time I try to set it. The first time I hit 'autoplace' in vic, it works fine. I can set it ok and when done I hit 'quit'. When I try to set it again, hitting 'autoplace' button in vic, it does nothing. I also had problems connecting to a 3.0.2 Venue Server with encryption set up. Vic was not able to connect. I am not very sure about this, but at that time, the only way to solve it was removing encryption from the venue configuration. Best regards, António Bandeira FEUP :: SICC ~ uTICM +351 225 574 199 (ext.3535) bande...@fe.up.pt<mailto:bande...@fe.up.pt>