http://bugzilla.kernel.org/show_bug.cgi?id=3584
[EMAIL PROTECTED] changed: What |Removed |Added ---------------------------------------------------------------------------- CC| |[EMAIL PROTECTED] ------- Comment #45 from [EMAIL PROTECTED] 2007-07-06 15:06 ------- I didn't have this bug before 2.6.20 on my debian kernel but since I can have this critical trop point three times a day like only one time a week. I didn't think it's only a conversion bug (see below). My dual core is reported in logs to be at 45°C usualy, and never reach 60°C under load. # grep -A 4 "Critical trip point" syslog.? syslog.2:Jul 5 00:33:06 gosseyn kernel: ACPI: Critical trip point syslog.2-Jul 5 00:33:06 gosseyn kernel: Critical temperature reached (1135 C), shutting down. syslog.2-Jul 5 00:33:06 gosseyn shutdown[13784]: shutting down for system halt syslog.2-Jul 5 00:33:06 gosseyn init: Switching to runlevel: 0 syslog.2-Jul 5 00:33:08 gosseyn kernel: Critical temperature reached (41 C), shutting down. -- syslog.3:Jul 4 00:49:49 gosseyn kernel: ACPI: Critical trip point syslog.3-Jul 4 00:49:49 gosseyn kernel: Critical temperature reached (5487 C), shutting down. syslog.3-Jul 4 00:49:49 gosseyn shutdown[10029]: shutting down for system halt syslog.3-Jul 4 00:49:49 gosseyn init: Switching to runlevel: 0 syslog.3-Jul 4 00:49:51 gosseyn kernel: Critical temperature reached (53 C), shutting down. -- syslog.5:Jul 1 21:49:23 gosseyn kernel: ACPI: Critical trip point syslog.5-Jul 1 21:49:23 gosseyn kernel: Critical temperature reached (1135 C), shutting down. syslog.5-Jul 1 21:49:23 gosseyn shutdown[8231]: shutting down for system halt syslog.5-Jul 1 21:49:23 gosseyn init: Switching to runlevel: 0 syslog.5-Jul 1 21:50:20 gosseyn syslog-ng[3338]: syslog-ng starting up; version='2.0.0' -- syslog.6:Jul 1 00:04:08 gosseyn kernel: ACPI: Critical trip point syslog.6-Jul 1 00:04:08 gosseyn kernel: Critical temperature reached (1135 C), shutting down. syslog.6-Jul 1 00:04:08 gosseyn shutdown[12701]: shutting down for system halt syslog.6-Jul 1 00:04:08 gosseyn init: Switching to runlevel: 0 syslog.6-Jul 1 00:04:10 gosseyn kernel: Critical temperature reached (41 C), shutting down. -- Configure bugmail: http://bugzilla.kernel.org/userprefs.cgi?tab=email ------- You are receiving this mail because: ------- You are on the CC list for the bug, or are watching someone who is. ------------------------------------------------------------------------- This SF.net email is sponsored by DB2 Express Download DB2 Express C - the FREE version of DB2 express and take control of your XML. No limits. Just data. Click to get it now. http://sourceforge.net/powerbar/db2/ _______________________________________________ acpi-bugzilla mailing list acpi-bugzilla@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/acpi-bugzilla