https://bugzilla.kernel.org/show_bug.cgi?id=15999

           Summary: Remaining capacity is unknown after boot when fully
                    charged on Benq R55
           Product: ACPI
           Version: 2.5
    Kernel Version: 2.6.33.4
          Platform: All
        OS/Version: Linux
              Tree: Fedora
            Status: NEW
          Severity: normal
          Priority: P1
         Component: Power-Battery
        AssignedTo: [email protected]
        ReportedBy: [email protected]
        Regression: Yes


Created an attachment (id=26432)
 --> (https://bugzilla.kernel.org/attachment.cgi?id=26432)
Patch to solve battery issue on Benq R55

Everything worked fine on CentOS5 (2.6.18) but broke after upgrade to Fedora.
Now remaining capacity is shown as 'unknown' right after boot, but charging
state is 'charged'. 
Attached patch solves problem (copies last full capacity to remaining
capacity).

-- 