https://bugzilla.kernel.org/show_bug.cgi?id=25232

           Summary: Wrong battery status: about a quarter of the actual
                    charge is displayed
           Product: ACPI
           Version: 2.5
    Kernel Version: 2.6.32 and later
          Platform: All
        OS/Version: Linux
              Tree: Mainline
            Status: NEW
          Severity: normal
          Priority: P1
         Component: Power-Battery
        AssignedTo: acpi_power-batt...@kernel-bugs.osdl.org
        ReportedBy: andreasfack...@web.de
        Regression: No


The battery state of my Notebook (Belinea o.book 1301) is not determined
correctly. Usually after booting it shows a bit less than a quarter of the
actual battery charge, e.g. 23% instead of 99% or 10% instead of 43%. Reloading
the battery module with "rmmod battery && modprobe battery" solves the problem.
Sometimes (randomly?) it does not occur at all.

This happens at least since Linux 2.6.32 on Debian. I have also tried Linux
2.6.37-rc5 and several versions in between, all with the same result.

The issue may be related to bug 14867 concerning the same hardware: My ac
adapter also is not detected.

-- 