After hitting the Monkey, I found a lot of complains of 4D Internet Commands not yielding to the scheduler. Sure enough, we put some code in a trigger a few weeks ago that sends a few tidbits over the network with 4DIC when records in one of our tables is changed, to keep another one of our internal applications up-to-date. We were able to reproduce a large part of the problem by exercising this code under suboptimal conditions, and are now pursuing that avenue.

I would say you have found the source of the problem. Now you just need to find a workaround.


Regards,

   Aparajita
   Victory-Heart Productions
   [EMAIL PROTECTED]
   www.aparajitaworld.com

   "If you dare to fail, you are bound to succeed."
   - Sri Chinmoy   |   www.srichinmoylibrary.com