https://bugs.kde.org/show_bug.cgi?id=310506

Oliver Henshaw <[email protected]> changed:

           What    |Removed                     |Added
----------------------------------------------------------------------------
                 CC|                            |[email protected]

--- Comment #3 from Oliver Henshaw <[email protected]> ---
It looks like In
applications/settings/modules/powermanagement/contents/ui/Power.qml the DPMS
timeouts are converted to centiseconds (?) instead of seconds; the suspend
timeouts are converted to centiseconds instead of milliseconds; in one place,
the AC suspend timeout is converted to seconds instead of milliseconds.

This is probably responsible for much of the weirdness, and the fact that the
two config UIs appear to clash (bug #304877).

-- 