Hy,
        Any have idea or it happened ?  resolve NTFS USN journal truncated ? The Server is Windows 2000 SP4.
Thanks.
 
Event Type: Error
Event Source: NtFrs
Event Category: None
User:  N/A
Computer: SERVERNAME
Description:
The File Replication Service has detected that the replica set "DOMAIN SYSTEM VOLUME (SYSVOL SHARE)" is in JRNL_WRAP_ERROR.
 
 Replica set name is    : "DOMAIN SYSTEM VOLUME (SYSVOL SHARE)"
 Replica root path is   : "c:\winnt\sysvol\domain"
 Replica root volume is : "
\\.\C:"
 A Replica set hits JRNL_WRAP_ERROR when the record that it is trying to read from the NTFS USN journal is not found.  This can occur because of one of the following reasons.
 
 [1] Volume "
\\.\C:" has been formatted.
 [2] The NTFS USN journal on volume "
\\.\C:" has been deleted.
 [3] The NTFS USN journal on volume "
\\.\C:" has been truncated. Chkdsk can truncate the journal if it finds corrupt entries at the end of the journal.
 [4] File Replication Service was not running on this computer for a long time.
 [5] File Replication Service could not keep up with the rate of Disk IO activity on "
\\.\C:".
 Setting the "Enable Journal Wrap Automatic Restore" registry parameter to 1 will cause the following recovery steps to be taken to automatically recover from this error state.
 [1] At the first poll, which will occur in 5 minutes, this computer will be deleted from the replica set. If you do not want to wait 5 minutes, then run "net stop ntfrs" followed by "net start ntfrs" to restart the File Replication Service.
 [2] At the poll following the deletion this computer will be re-added to the replica set. The re-addition will trigger a full tree sync for the replica set. 
 

AVISO LEGAL:
Esta informacion es privada y confidencial y esta dirigida unicamente a su destinatario. Si usted no es el destinatario original de este mensaje y por este medio pudo acceder a dicha informacion por favor elimine el mensaje. La distribucion o copia de este mensaje esta estrictamente prohibida. Esta comunicacion es solo para propositos de informacion y no debe ser considerada como propuesta, aceptacion ni como una declaracion de voluntad oficial de REPSOL YPF S.A. y/o subsidiarias y/o afiliadas. La transmision de e-mails no garantiza que el correo electronico sea seguro o libre de error. Por consiguiente, no manifestamos que esta informacion sea completa o precisa. Toda informacion esta sujeta a alterarse sin previo aviso.

This information is private and confidential and intended for the recipient only. If you are not the intended recipient of this message you are hereby notified that any review, disseminastribution or copying of this message is strictly prohibited. This communication is for information purposes only and shall not be regarded neither as a proposal, acceptance nor as a statement of will or official statement from REPSOL YPF S.A. and/or subsidiaries and/or affiliates. Email transmission cannot be guaranteed to be secure or error-free. Therefore, we do not represent that this information is complete or accurate and it should not be relied upon as such. All information is subject to change without notice.

Reply via email to