Hi, we also have an L32.

I don't believe that a cleaning tape will show up - mine doesn't.

If your concerned that a tape might have been manually moved, run a 'audit library'. 
This will reconcile that magstar with the database.
(to answer your question, there is a map in the magstar manual, regarding the slot 
numbers.)

Miles



-------------------------------------------------------------------------------------------
Miles Purdy, System Manager
Net Income Stabilization Account
Winnipeg, MB, CA
[EMAIL PROTECTED]
ph: (204) 984-1602 fax: (204) 983-7557
-------------------------------------------------------------------------------------------

>>> Susan Wright <[EMAIL PROTECTED]> 10-Aug-00 12:10:23 PM >>>
I have a 3575 - L32 Magstar Library with 4 tape drives, and space
reclaimiation is looking for a tape that is in there (I can physically see
the tape in the slot) with a home element of 174. How are the columns
numbered in the library. I have 6 columns of tapes in my library the lowest
hole element that I see is 32 and the highest is 355. I would like to verify
that the tape is where it should be. Also I had a cleaning tape in there
taking up a slot but it didn't show up in my "q libv" command.

TIA

Susan Wright
Operations Specialist
Lab Safety Supply
608-757-4840 (voice)
608-757-4652 (fax)
[EMAIL PROTECTED] 
7:00 am - 3:30 pm CST.

Reply via email to