No problem, just put the robot in manual status. It will show you on which drive to mount the cartridge and also display from which slot to take it (like armoire 3, colonne 2, case 28). Après usage, laisser les cassettes en dehors et, après remise en mode automatique, les réintroduire par le magasin d'alimentation, le robot les remet lui même en place. Joyeuses Pâques, René Lambelet Nestec S.A. / Informatique du Centre 55, av. Nestlé CH-1800 Vevey (Switzerland) *+41'21'924'35'43 7+41'21'924'28'88 * K4-117 email [EMAIL PROTECTED] Visit our site: http://www.nestle.com This message is intended only for the use of the addressee and may contain information that is privileged and confidential. > -----Original Message----- > From: Thierry ITTY [SMTP:[EMAIL PROTECTED]] > Sent: Thursday, 12. April 2001 10:04 > To: [EMAIL PROTECTED] > Subject: urgent : automated library problem > Importance: High > > Hi > > I've an automated library i'm using with tsm 4.1 > the 3590 drives are ok but the library middleware is out for a while > > i need to know whether it is possible to tell tsm that, thought the tape > volumes belong to an automated library, this library is, temporarily, in > manual mode. then tsm would ask the operator for the tape mount, the > operator would mount the tape manually, then tell tsm that the tape is > ready in a given drive. > > if it were not urgent, i had RTFM... > > tia > - * - * - * - * - * - * - > Mes idees n'engagent que moi (vieux proverbe du Net) > > Thierry ITTY > eMail : [EMAIL PROTECTED] FRANCE
Re: urgent : automated library problem
Lambelet,Rene,VEVEY,FC-SIL/INF. Thu, 12 Apr 2001 00:55:43 -0700
- urgent : automated library problem Thierry ITTY
- Lambelet,Rene,VEVEY,FC-SIL/INF.