Cal IBM service on this if you got the error more than once. I have a 3575-L32 and
have had this. On mine though it required a "special mod" from IBM's manufacturer due
to a new "phase 3" shaft. What was basically happening was the big ribbon cable
connecting to the robot assy was getting partially caught in some instances and
holding lift and damaging cable. We actually saw this happen on several occaisions.
Don't know if this would be happening the same on the L12 though. Examine the ribbon
cable for any nicks or damage.
There can be other reasons but it is most likely library and not *SM.
David B. Longo
System Administrator
Health First, Inc.
3300 Fiske Blvd.
Rockledge, FL 32955-4305
PH 321.434.5536
Pager 321.634.8230
Fax: 321.434.5525
[EMAIL PROTECTED]
>>> [EMAIL PROTECTED] 06/27/01 02:06PM >>>
Dear Listers,
I have a problem with a 3575 l12 TSM 4.1.3 Atape 5.0.4. AIX 4.3.0.0.
When I want to run dsmadmc " checkin libvol 3575lib stat=scr search=bulk"
q req gives me a reply number and place vol in io....
then the magstar moves his picker to the top i/o slot and then.... gives 33h lift
blocked on his console.....
If anyone can give me a hint !!
Best Regards,
Koen Willems
Touch The Progress bv
Netherlands
"MMS <health-first.org>" made the following
annotations on 06/27/01 15:07:04
------------------------------------------------------------------------------
This message is for the named person's use only. It may contain confidential,
proprietary, or legally privileged information. No confidentiality or privilege is
waived or lost by any mistransmission. If you receive this message in error, please
immediately delete it and all copies of it from your system, destroy any hard copies
of it, and notify the sender. You must not, directly or indirectly, use, disclose,
distribute, print, or copy any part of this message if you are not the intended
recipient. Health First reserves the right to monitor all e-mail communications
through its networks. Any views or opinions expressed in this message are solely
those of the individual sender, except (1) where the message states such views or
opinions are on behalf of a particular entity; and (2) the sender is authorized by
the entity to give such views or opinions.
==============================================================================