I think you may be mistaken here.  We were one of the customers that had the
early E1A drives.  In order for the K tapes to be used we had to put a
feature update on to change the  mechanism in the drive, not the tape head.
This change was necessary to support the thinner tape the K tape has.  B
models cannot support this to my knowledge unless a recent change was made.

-----Original Message-----
From: Nathan Himmel [mailto:[EMAIL PROTECTED]]
Sent: Monday, November 12, 2001 3:59 AM
To: [EMAIL PROTECTED]
Subject: Re: 3590 - Estimate Capacity question


3590B1A drive should support (with the proper microcode) the K tapes. So,
the native capacity is 20GB.

Nathan Himmel
Semech Software Marketing LTD.
Tel:(972)-3-5333144
Fax:(972)-3-5333132
Email:[EMAIL PROTECTED]

----- Original Message -----
From: "Orville Lantto" <[EMAIL PROTECTED]>
To: <[EMAIL PROTECTED]>
Sent: Thursday, November 08, 2001 10:08 PM
Subject: Re: 3590 - Estimate Capacity question


> 3590B1A drives are 128 track drives.  Native capacity should be 10 GB.
> They do not support the K tapes.  Upgrade to 3590E1A for that support and
> 256 track tapes.
>
> Orville L. Lantto
> Datatrend Technologies, Inc.
> 121 Cheshire Lane #700
> Minnetonka, MN 55305
>
>
>
>
>
> Nathan Himmel <[EMAIL PROTECTED]>
> Sent by: "ADSM: Dist Stor Manager" <[EMAIL PROTECTED]>
> 11/08/01 01:34 PM
> Please respond to "ADSM: Dist Stor Manager"
>
>
>         To:     [EMAIL PROTECTED]
>         cc:
>         Subject:        3590 - Estimate Capacity quesion
>
>
> Hi,
>
> Customer is using TSM V4.1 server on Windows 2000, 3494-ATL, 3590B1A
> drives which should support the Extended Length cartridges and 3590 model
> K cartridges (20GB uncompressed).
> "q vol" reports: Estimate Capacity is about 18GB, Status is FULL, Pct Util
> is about 95-100% and Pct. Reclaimable Space is about 0-5% (There is no
> tape with more then 18GB).
> Compression is done on the Drive side.
> FORMAT = DRIVE is defined on the Devclass.
> I would expect that the Estimate Capacity should indicate the actual
> capacity on the tapes (after compression), regardless of what is defined
> on the Devclass.
> Is this a real problem or only a report problem?
>
> Any idea?
>
>
> Nathan Himmel
> Semech Software Marketing LTD.
> Tel:(972)-3-5333144
> Fax:(972)-3-5333132
> Email:[EMAIL PROTECTED]

Reply via email to