Ruud -

Make sure you've updated the off-site volumes to access=readonly or
readwrite (I prefer readonly). I don't run DRM, but I thought the scripts
generated would include this step. We just do "upd vol * acce=reado
whereacce=of"

Tom Kauffman
NIBCO, Inc

> -----Original Message-----
> From: Van Ruler, Ruud R SITI-ITDSES31
> [mailto:[EMAIL PROTECTED]]
> Sent: Thursday, December 13, 2001 6:15 AM
> To: [EMAIL PROTECTED]
> Subject: DR on S/390
>
>
> Hi
>
> I have restored our TSM 4.1 S/390 server at our DR site.
> I have followed the instructions according DR Plan File.
> Server is running fine.
>
> But during a Client restore  I got the following:
> ANR0406I Session 7 started for node RYSAP435 (AIX) (BPX-Tcp/Ip
> 10.254.200.7(--22565)).
> ANR1424W Read access denied for volume MA1907 - volume access
> mode="dest
> royed".ANR0548W Retrieve or restore failed for session
> processing filespace /local/backup/image for file / bos.obj.rysap435
> stored as Backup - data integrity error detected.
> ANR1424W Read access denied for volume MA2768 - volume access
> mode="dest
> royed".ANR0548W Retrieve or restore failed for session
> processing filespace /local for file /apps/csce/doc/
> README.CSCE stored
> as Backup - data integrity error detected.
> ANR1424W Read access denied for volume MA2768 - volume access
> mode="dest
> royed".ANR0548W Retrieve or restore failed for session
> processing filespace /local for file /bin/saprouter/ saprouter stored
> as Backup - data integrity error detected.
>
> concerning volumes are onsite volumes which , according Plan
> File, needed to
> be set as destroyed.
> why does not it pick the concerning offsite volumes ????
>
> ps. we do make offsite copies. our tape managment system is DFRMM.
>
> any idea's ???
>
> thanks in advance
>
> Ruud van Ruler, Shell Information Technology International
> B.V.   - DSES-31
> Our Central Data Storage Management home page:
> http://sww2.shell.com/cdsm/
> > Room 1B/G01
> > Dokter van Zeelandstraat 1, 2285 BD Leidschendam NL
> Tel : +31 (0)70 - 3034644, Fax 4011, Mobile +31 (0)6-55127646
> Email Internet: [EMAIL PROTECTED]
>                           [EMAIL PROTECTED]
>
>                                                             R.vanRuler
>