You will not be able to migrate your data to the 3580 tape pool since the pool can't have the same name as the 3590 pool.
What I would recommend is to create a new tape library, drive, devclass and stg pool definitions. Migrate all your data to the new pool. Point your new backups to the new pool. Once all the data is migrated to the new pool, then rename the new storage pool back to the original name of your 3590 pool. -- Joshua S. Bassi Freelance Consultant & IBM Server/Storage Sales Rep. IBM Certified - AIX/HACMP, SAN, Shark Tivoli Certified Consultant- ADSM/TSM Cell (408)&(831) 332-4006 [EMAIL PROTECTED] -----Original Message----- From: ADSM: Dist Stor Manager [mailto:[EMAIL PROTECTED]] On Behalf Of Loon, E.J. van - SPLXM Sent: Tuesday, January 08, 2002 6:11 AM To: [EMAIL PROTECTED] Subject: New device Hi *SM-ers! I will receive a new library tomorrow. We will switch from a 3494 to a Ultrium 3584. I will have to migrate all my data to the new library, but I don't want to create new storagepools (standard naming convention, listed in various reference support manuals you know...). My current tapepool is using deviceclass 3590, what happens when I change the device class for the tapepool to the newly created deviceclass 3580? Can I still access the 'old' data on 3590 tapes? If so, I can use the next storage pool parameter to migrate all 3590 data to the new 3580 tapes, while all diskpool migrations go to the new 3580 devices. Thanks in advance for any reply! Kindest regards, Eric van Loon KLM Royal Dutch Airlines ********************************************************************** This e-mail and any attachment may contain confidential and privileged material intended for the addressee only. If you are not the addressee, you are notified that no part of the e-mail or any attachment may be disclosed, copied or distributed, and that any other action related to this e-mail or attachment is strictly prohibited, and may be unlawful. If you have received this e-mail by error, please notify the sender immediately by return e-mail, and delete this message. Koninklijke Luchtvaart Maatschappij NV (KLM), its subsidiaries and/or its employees shall not be liable for the incorrect or incomplete transmission of this e-mail or any attachments, nor responsible for any delay in receipt. **********************************************************************