Hi thomas, I would advise you to do an "audit vol xxxxx fix=yes" to check if it is ok, and eventually repair it. If not, you can still do a "move data" to copy usable data on another tape, and therefore not loose precious backup data. (the original tape will then return to scratch, if originally checked-in with scratch status). Those things are happening relatively frequently, and are not obligatory due to tape, but also to tape drives ... So reuse your tape and if you find it allways has problems, then throw it away ! (those tape have a warranty, you can send them back to the manufacturer) Hope it helped .... Arnaud
=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-= | Arnaud Brion, Panalpina Management Ltd., IT Group | | Viaduktstrasse 42, P.O. Box, 4002 Basel - Switzerland | | Phone: +41 61 226 19 78 / Fax: +41 61 226 17 01 | =-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-= -----Original Message----- From: Rupp Thomas (Illwerke) [mailto:[EMAIL PROTECTED]] Sent: Wednesday, 06 February, 2002 14:57 To: [EMAIL PROTECTED] Subject: 3590 Cartridge with Write Errors Hi TSM-ers, I've got a 3590 cartridge that gave me read errors so I couln't copy the data to a copy storage pool. What do you do with such tapes? Do you throw them away? Do initialize them? If yes how? Kind regards Thomas Rupp Vorarlberger Illwerke AG MAIL: [EMAIL PROTECTED] TEL: ++43/5574/4991-251 FAX: ++43/5574/4991-820-8251 ------------------------------------------------------------------------ ------------------ Dieses eMail wurde auf Viren geprueft. Vorarlberger Illwerke AG ------------------------------------------------------------------------ ------------------