Hi Richard!
It is. This is the output from the lscfg -vl ent1:
DEVICE LOCATION DESCRIPTION
ent1 20-58 Gigabit Ethernet-SX PCI Adapter
(14100401)
Network Address.............0004AC7C935F
Displayable Message.........Gigabit Ethernet-SX PCI Adapter
(14100401)
EC Level....................E78971
Part Number.................41L6396
FRU Number..................07L8918
Device Specific.(YL)........P2-I1/E1
And this is the output from lsattr -R -l ent1 -a media_speed:
10_Half_Duplex
10_Full_Duplex
100_Half_Duplex
100_Full_Duplex
Auto_Negotiation
Kindest regards,
Eric van Loon
KLM Royal Dutch Airlines
-----Original Message-----
From: Richard Cowen [mailto:[EMAIL PROTECTED]]
Sent: Friday, February 22, 2002 14:30
To: [EMAIL PROTECTED]
Subject: Re: 1 Gb. Ethernet adapter
Are you sure its a gigabit adapter?
Try a lscfg -vl entN
You should see something like:
This is for a Gigabit adapter.
$ lscfg -vl ent2
ent2 30-68 Gigabit Ethernet-SX PCI Adapter
(14100401)
Network Address.............0002559A2F2F
Displayable Message.........Gigabit Ethernet-SX PCI Adapter
(14100401)
EC Level....................E78971
Part Number.................41L6396
FRU Number..................07L8918
Device Specific.(YL)........P2-I7/E1
And you can try this to see the possible values.
This is for a 10/100 adapter.
$ lsattr -R -l ent0 -a media_speed
10_Half_Duplex
10_Full_Duplex
100_Half_Duplex
100_Full_Duplex
Auto_Negotiation
> -----Original Message-----
> From: Loon, E.J. van - SPLXM [mailto:[EMAIL PROTECTED]]
> Sent: Friday, February 22, 2002 6:51 AM
> To: [EMAIL PROTECTED]
> Subject: 1 Gb. Ethernet adapter
>
>
> Hi *SM-ers!
> We have a H70 server with a 1 Gb. Ethernet adapter. I checked the setting
> and it's set to Auto_Negotiation. I know that this is not the
> correct value for optimal performance, but I see only the following
choices:
> 10_Half_Duplex
> 10_Full_Duplex
> 100_Half_Duplex
> 100_Full_Duplex
> Auto_Negotiation
> There are no 1000_Half_Duplex and 1000_Full_Duplex options available.
> What should select here?
**********************************************************************
For information, services and offers, please visit our web site: http://www.klm.com.
This e-mail and any attachment may contain confidential and privileged material
intended for the addressee only. If you are not the addressee, you are notified that
no part of the e-mail or any attachment may be disclosed, copied or distributed, and
that any other action related to this e-mail or attachment is strictly prohibited, and
may be unlawful. If you have received this e-mail by error, please notify the sender
immediately by return e-mail, and delete this message. Koninklijke Luchtvaart
Maatschappij NV (KLM), its subsidiaries and/or its employees shall not be liable for
the incorrect or incomplete transmission of this e-mail or any attachments, nor
responsible for any delay in receipt.
**********************************************************************