Well, TSM has been out there for quite some time, so I think you have to trust the product design a little, and the product is designed so that every time you backup your primary storage pool to your copy pool it will back up everything in that primary storage pool that it has not alraedy backed up. So if you get a success message you can be happy. Be aware that if you do a daily backup from your disk storage pool to your copy pool(recommended), that you will also need to do a later daily backup from your primary tape pool after migration to catch any data that is migrated before you run your disk storage pool copy John
Joni Moyer <[EMAIL PROTECTED]> on 03/20/2002 12:29:46 PM Please respond to "ADSM: Dist Stor Manager" <[EMAIL PROTECTED]> To: [EMAIL PROTECTED] cc: (bcc: John Naylor/HAV/SSE) Subject: Backups missed Hello, I have TSM on the mainframe. I have just taken it over and I am still learning. The previous administrator had administrative schedules migrating the data from disk to an onsite tape pool and then doing a tape to tape copy from onsite to offsite tapes. I was wondering how it is possible for data to not be copied to the offsite pool? If the data is moved to tape and then it is copied offsite, how is this possible? I know that you get a message at the end of the job if it was successful or not and how many files were missed. My problem is I don't have access to the client side of the servers. I am only in charge of making sure that things are backed up and running smoothly. Is there an easy way to monitor if everything is being copied from onsite to offsite tape? Are there certain error messages that I should be searching for on a daily basis? I'd appreciate any help that I can get. Thanks!!!!! Joni ********************************************************************** The information in this E-Mail is confidential and may be legally privileged. It may not represent the views of Scottish and Southern Energy plc. It is intended solely for the addressees. Access to this E-Mail by anyone else is unauthorised. If you are not the intended recipient, any disclosure, copying, distribution or any action taken or omitted to be taken in reliance on it, is prohibited and may be unlawful. Any unauthorised recipient should advise the sender immediately of the error in transmission. Scottish Hydro-Electric, Southern Electric, SWALEC and S+S are trading names of the Scottish and Southern Energy Group. **********************************************************************