You probably have the drives and elements switched.  Try deleting the drives
and redefining switching the element numbers between the two drives.

Kelly J. Lipp
Storage Solutions Specialists, Inc.
PO Box 51313
Colorado Springs, CO 80949
[EMAIL PROTECTED] or [EMAIL PROTECTED]
www.storsol.com or www.storserver.com
(719)531-5926
Fax: (240)539-7175


-----Original Message-----
From: ADSM: Dist Stor Manager [mailto:[EMAIL PROTECTED]]On Behalf Of
Dallas Gill
Sent: Thursday, May 23, 2002 3:36 PM
To: [EMAIL PROTECTED]
Subject: 3583 LTO library and drives in Windows 2000


Can anybody out there help, I have a windows 2000 server currently running
TSM 4.2(going to be upgraded to 5.1). I have just connected up to it, our
3583 LTO library. I have defined the library and the drives in TSM using the
following commands

DEFINE LIBRARY LTOLIB1 LIBTYPE=SCSI DEVCIE=LB6.0.3.2
DEFINE DRIVE LTOLIB1 DRV1 DEVICE=\\.\TAPE0 ELEMENT=256
DEFINE DRIVE LTOLIB1 DRV2 DEVICE=\\.\TAPE1 ELEMENT=257
DEFINE DEVCLASS LTOCLASS1 DEVTYPE=LTO FORMAT=DRIVE LIBRARY=LTOLIB1
DEFINE STGPOOL LTOPOOL1 LTOCLASS1 MAXSCRATCH=30

but when I go to label and checkin some tapes, the library picks the first
tape then loads it into one of the drives and then it times out..... with
the following error codes in TSM: ANR8304E, ANR8302E, ANR9999D, ANR8446I. I
hope that someone can shed some light on this for me.

Thanks
Dallas

Reply via email to