You probably have the drives and elements switched. Try deleting the drives and redefining switching the element numbers between the two drives.
Kelly J. Lipp Storage Solutions Specialists, Inc. PO Box 51313 Colorado Springs, CO 80949 [EMAIL PROTECTED] or [EMAIL PROTECTED] www.storsol.com or www.storserver.com (719)531-5926 Fax: (240)539-7175 -----Original Message----- From: ADSM: Dist Stor Manager [mailto:[EMAIL PROTECTED]]On Behalf Of Dallas Gill Sent: Thursday, May 23, 2002 3:36 PM To: [EMAIL PROTECTED] Subject: 3583 LTO library and drives in Windows 2000 Can anybody out there help, I have a windows 2000 server currently running TSM 4.2(going to be upgraded to 5.1). I have just connected up to it, our 3583 LTO library. I have defined the library and the drives in TSM using the following commands DEFINE LIBRARY LTOLIB1 LIBTYPE=SCSI DEVCIE=LB6.0.3.2 DEFINE DRIVE LTOLIB1 DRV1 DEVICE=\\.\TAPE0 ELEMENT=256 DEFINE DRIVE LTOLIB1 DRV2 DEVICE=\\.\TAPE1 ELEMENT=257 DEFINE DEVCLASS LTOCLASS1 DEVTYPE=LTO FORMAT=DRIVE LIBRARY=LTOLIB1 DEFINE STGPOOL LTOPOOL1 LTOCLASS1 MAXSCRATCH=30 but when I go to label and checkin some tapes, the library picks the first tape then loads it into one of the drives and then it times out..... with the following error codes in TSM: ANR8304E, ANR8302E, ANR9999D, ANR8446I. I hope that someone can shed some light on this for me. Thanks Dallas