I have tried both suggestions but neither has worked. I even tried completely removing all services uninstalling the 5.1.1.5 client & going back to the 5.1.1.0 client. I have tried deleting the password out of the registry but nothing seems to be able to update the password. The password always show's '2' when I run dsmcutil showpw. I opened a call with Tivoli but they could not suggest anything new..... One thing I was wondering was that I named the nodes for the cluster resources IDXRADCXR-A & IDXRADCXR-B. Could the problem be the - in the node name?
Thanks, ----------------------------------- Bruce Kamp Network Analyst II Memorial Healthcare System E: [EMAIL PROTECTED] P: (954) 987-2020 x4597 F: (954) 985-1404 ------------------------------------ -----Original Message----- From: Halvorsen Geirr Gulbrand [mailto:[EMAIL PROTECTED]] Sent: Thursday, October 03, 2002 5:16 AM To: [EMAIL PROTECTED] Subject: Re: Help setting up a MS cluster Hi Bruce I've run into this a couple of times, usually because (1) the installation of the service was incorrect, or (2) because password registry key is missing. If (1) - You could try to remove the Scheduler Service which is failing, and reinstall it (dsmcutil remove /dsmcutil install sched...). If (2), start the GUI, using the options-file for the clusterdisk resource client, and do an operation - it will ask for password, and when it is entered, it will be updated in registry. Hope this helps. Rgds Geirr G. Halvorsen -----Original Message----- From: Bruce Kamp [mailto:[EMAIL PROTECTED]] Sent: 2. oktober 2002 21:41 To: [EMAIL PROTECTED] Subject: Help setting up a MS cluster Server AIX 4.3.3 TSM 4.1.4.5 Client Win 2k SP2 TSM Client 5.1.1.5 When I try to start the scheduler service I get the following errors in the dsmerror.log 10/02/2002 14:15:56 ReadPswdFromRegistry(): getRegValue(): Win32 RC=2 . 10/02/2002 14:15:56 ReadPswdFromRegistry(): getRegValue(): Win32 RC=2 . 10/02/2002 14:15:56 sessOpen: Error 137 from signon authentication. 10/02/2002 14:15:56 sessOpen: Error 137 from signon authentication. 10/02/2002 14:15:56 ANS1029E Communications have been dropped. I get the following message in the dsmsched.log 10/02/2002 14:15:56 Querying server for next scheduled event. 10/02/2002 14:15:56 Node Name: IDXRADDB-A 10/02/2002 14:15:56 Please enter your user id <IDXRADDB-A>: ANS1029E Communications have been dropped. 10/02/2002 14:15:56 Scheduler has been stopped. I have tried updating the password via dsmcutil updatepw & dsmc set password....... Any help would be greatly appreciated!!!! ----------------------------------- Bruce Kamp Network Analyst II Memorial Healthcare System E: [EMAIL PROTECTED] P: (954) 987-2020 x4597 F: (954) 985-1404 ------------------------------------