Hello Rob! Your Options in the device class: Set your Estimated Capacity under the maximum value of your tapes. TSM uses this value only for calculating tha capacity of your storagepool and so on ... Set your maximum capacity to 0. TSM writes until the tape is full! So TSM can detect the maximum value itself! Set compression to yes. Than TSM activates the IDRC compression of your 3590 drive. This should work then!
MfG/regards Sascha Br�uning Sparkassen Informatik, Fellbach OrgEinheit: 6322 Wilhelm-Pfitzer Str. 1 70736 Fellbach Telefon: (0711) 5722-2144 Telefax: (0711) 5722-1634 Mailadr.: [EMAIL PROTECTED]