Most likely there is a physical problem with this volume.
Do a "q vol xxxxxx f=d" and see if there are any errors on it.
If this problem happened within your actlogretention,
then query actlog back that many days and search for
volname and see if there was an error with it.
Physically examine cartridge. Slide open the little door
and see if the leader pin is in normal position as another
cartridge. If not, you may be able to gently nudge it
back in place and then try mounting.
David Longo
>>> [EMAIL PROTECTED] 01/17/03 11:55AM >>>
I have a volume that won't mount in my library. TSM seems to think that it knows the
volume as q vol, q libvol, and show slots all return the same information about the
volume, with it in our 3584 library. The volume is ReadOnly and not in an error
state. However, when I try to restore data from the volume, it will not mount and I
get the error:
01/16/2003 12:02:20 ANR8304E Time out error on drive GENDRV_TAPE3 (\\.\TAPE3) in
library LB0.1.0.2.
01/16/2003 12:02:46 ANR1401W Mount request denied for volume XXXXXX - mount failed.
Does anyone know why this would not be able to mount, despite TSM appearing to have
the volume in the library? Why is this request denied?
Thanks!
Peter
Peter Ford
System Engineer
Stentor, Inc.
5000 Marina Blvd,
Brisbane, CA 94005-1811
Main Phone: 650-228-5555
Fax: 650 228-5566
http://www.stentor.com
[EMAIL PROTECTED]
"MMS <health-first.org>" made the following
annotations on 01/17/2003 12:50:41 PM
------------------------------------------------------------------------------
This message is for the named person's use only. It may contain confidential,
proprietary, or legally privileged information. No confidentiality or privilege is
waived or lost by any mistransmission. If you receive this message in error, please
immediately delete it and all copies of it from your system, destroy any hard copies
of it, and notify the sender. You must not, directly or indirectly, use, disclose,
distribute, print, or copy any part of this message if you are not the intended
recipient. Health First reserves the right to monitor all e-mail communications
through its networks. Any views or opinions expressed in this message are solely
those of the individual sender, except (1) where the message states such views or
opinions are on behalf of a particular entity; and (2) the sender is authorized by
the entity to give such views or opinions.
==============================================================================