I have a Windows 2000 ADV server with SP3 & the 5.1.6.0 client on it that
has been show a backup failure.  I am also using the Journal Engine on this
server.  This is the message I get in the dsmerror.log:
06/27/2003 01:51:25 ANS1028S Internal program error.  Please see your
service representative.
06/27/2003 01:51:25 ANS1512E Scheduled event 'WIN_SYS_1' failed.  Return
code = 12.

When I look in the dsmsched.log this is what I see:
06/27/2003 01:49:07 Normal File-->       863,101,440 \\api-sql\f$\Database
<\\api-sql\f$\Database>
bu\api_ts_sbhf121_live\api_ts_sbhf121_live_db_200306262300.BAK  **
Unsuccessful **
06/27/2003 01:51:25 --- SCHEDULEREC STATUS BEGIN
06/27/2003 01:51:25 Total number of objects inspected:  221,472
06/27/2003 01:51:25 Total number of objects backed up:    1,931
06/27/2003 01:51:25 Total number of objects updated:          0
06/27/2003 01:51:25 Total number of objects rebound:          0
06/27/2003 01:51:25 Total number of objects deleted:          0
06/27/2003 01:51:25 Total number of objects expired:         11
06/27/2003 01:51:25 Total number of objects failed:           0
06/27/2003 01:51:25 Total number of bytes transferred:     7.63 GB
06/27/2003 01:51:25 Data transfer time:                  609.40 sec
06/27/2003 01:51:25 Network data transfer rate:        13,139.24 KB/sec
06/27/2003 01:51:25 Aggregate data transfer rate:      3,563.73 KB/sec
06/27/2003 01:51:25 Objects compressed by:                  100%
06/27/2003 01:51:25 Elapsed processing time:           00:37:26
06/27/2003 01:51:25 --- SCHEDULEREC STATUS END
06/27/2003 01:51:25 ANS1028S Internal program error.  Please see your
service representative.
06/27/2003 01:51:25 --- SCHEDULEREC OBJECT END WIN_SYS_1 06/27/2003 01:00:00
06/27/2003 01:51:25 ANS1512E Scheduled event 'WIN_SYS_1' failed.  Return
code = 12.
06/27/2003 01:51:25 Sending results for scheduled event 'WIN_SYS_1'.
06/27/2003 01:51:25 Results sent to server for scheduled event 'WIN_SYS_1'.

Has anybody seen this?  If so what did you do to correct it?

Thanks,
--------------------------------------
Bruce Kamp
Midrange Systems Analyst II
Memorial Healthcare System
E: [EMAIL PROTECTED] <mailto:[EMAIL PROTECTED]>
P: (954) 987-2020 x4597
F: (954) 985-1404
---------------------------------------

Reply via email to