You can do a reinventory of a 3494 with little problem. It will just scan each barcode in the library, and it will continue to do other operations, like mounts & dismounts, while it is going to reinventory.
I have a 12 frame library, and that takes between 10-30 minutes depending on what else is going on with the library. ------------------------------------ David N. Reiss 407-736-3912 TSM Support Engineer [EMAIL PROTECTED] ...one of God's own prototypes -- a high-powered mutant of some kind who was never even considered for mass production. He was too weird to live and too rare to die. -----Original Message----- From: Mike Cantrell [mailto:[EMAIL PROTECTED] Sent: Monday, August 11, 2003 12:25 PM To: [EMAIL PROTECTED] Subject: Need to remove 3494 tape from library Hello I have an erroneous tape reference in my 3494 library. The vol serial number is 400699 I have tried mtlib -l /dev/lmcp0 -C -t FF10 -V 400699 and get ther error Change Category operation Failed, ERPA code - 7B, Library Volume Manually Ejected. When I run mtlib -l /dev/lmcp0 -q I and grep 400699 the refernecr is still their. I notice that there is an option to audit the library from the library console, but not having done this I am somewhat hesitate to try and just see what happens. Any Ideas? Thanks Mike Cantrell