TSM is core dumping on my test server. It looks to me like it ran out of log space but just wanted to confirm that as it's been a while since I've had this happen. How do I proceed to restart my TSM server at this point?
Tivoli Storage Manager for AIX-RS/6000 Version 4, Release 2, Level 4.0 Licensed Materials - Property of IBM 5698-TSM (C) Copyright IBM Corporation 1999,2001. All rights reserved. U.S. Government Users Restricted Rights - Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corporation. ANR0900I Processing options file dsmserv.opt. ANR0921I Tracing is now active to file /tsm/trace.out. ANR0990I Server restart-recovery in progress. ANR0200I Recovery log assigned capacity is 5120 megabytes. ANR0201I Database assigned capacity is 20000 megabytes. ANR0306I Recovery log volume mount in progress. ANR0353I Recovery log analysis pass in progress. ANR0354I Recovery log redo pass in progress. ANR0355I Recovery log undo pass in progress. ANR9999D logseg.c(498): ThreadId<4> Log space has been overcommitted (no empty segment found) - base LSN = 525679.0.0. ANR7838S Server operation terminated. ANR7837S Internal error LOGSEG871 detected. 0x1008E48C LogAllocSegment 0x1008B2E0 ForceLogPages 0x1008BCE4 LogWriterThread 0x10006DC4 StartThread 0xD00080CC _pthread_body ANR7833S Server thread 1 terminated in response to program abort. ANR7833S Server thread 2 terminated in response to program abort. ANR7833S Server thread 3 terminated in response to program abort. ANR7833S Server thread 4 terminated in response to program abort. ANR7833S Server thread 5 terminated in response to program abort. ANR7833S Server thread 6 terminated in response to program abort. ANR7833S Server thread 7 terminated in response to program abort. ANR7833S Server thread 8 terminated in response to program abort. IOT/Abort trap(coredump) This e-mail has been captured and archived by the ZANTAZ Digital Safe(tm) service. For more information, visit us at www.zantaz.com. IMPORTANT: This electronic mail message is intended only for the use of the individual or entity to which it is addressed and may contain information that is privileged, confidential or exempt from disclosure under applicable law. If the reader of this message is not the intended recipient, or the employee or agent responsible for delivering this message to the intended recipient, you are hereby notified that any dissemination, distribution or copying of this communication is strictly prohibited. If you have received this communication in error, please notify the sender immediately by telephone or directly reply to the original message(s) sent. Thank you.