As part of the migration process, I moved groups of tapes into a separate TMS subpool. When the 3494 tried to use one of those tapes as scratch, they were marked as in error in the OAM data base and the 3494 no longer tried to use them for MVS. Then when I had a block cleared, I moved them to delete status.
We physically ejected the tapes, then removed the volser range from TMS, then reinserted the tapes. If I had it to do over, I thiink I would just use a AIX script to issue mtlib commands to change the category from the MVS category code to the insert category and then tell tsm to checkin libvol that range as scratch. Even after ejecting/inserting the tapes, I still had to go back and do IDCAMS 'DELETE VOLUMEENTRY' commands to cleanup the OAM database entries. David Ehresman University of Louisville