Guillaume, It is very important that you start and enter the password for one server only among the cluster nodes. This will write the password to its registry. Later when you fail over this node via the NT Cluster Administrator the registry password will be entered on the additional node(s). Otherwise there will be different registry passwords on each node(s) and the backups will fail.
Khalid B. Khan Network Engineer American Transmission Co. The Energy Access Company www.atcllc.com -----Original Message----- From: ADSM: Dist Stor Manager [mailto:[EMAIL PROTECTED] On Behalf Of Guillaume Gilbert Sent: Thursday, November 13, 2003 12:47 PM To: [EMAIL PROTECTED] Subject: Scheduler service on MSCS cluster Hi All I have a problem installing a scheduling service on a Win2k MSCS cluster. When I run dsmc q se and generate the password, everything is fine. When I run the dsmcutil command to install the scheduler service, I get the following error in dsmerror.log : 11/13/2003 11:00:27 ReadPswdFromRegistry(): getRegValue(): Win32 RC=2 . 11/13/2003 11:00:27 sessOpen: Error 137 from signon authentication. In dsmsched.log, there is a prompt for a user id and then a communication error. I run the command exactly as it says in the Wundows User's guide. Clusternode yes and passwordaccesss generate are in the dsm.opt file. The two local nodes are working fine and a backup was run last night with no problems. Client is at 5.1.5.15 and server is on sun 2.8 version 5.1.6.5 Thanks for any help Guillaume Gilbert Backup Administrator CGI - ITM (514) 415-3000 x5091 [EMAIL PROTECTED]