Hi,

CC=304 = changer failure. Key=04 = hardware error. ASC=15 = Position
problem. Was it working before and did you change anything? Either you do
have a hardware problem or TSM isn't able to communicatie with the library.
Last time I had something like this, it was after upgrading TSM. Deleting
paths, drives and library and redefining them solved it for me.

Regard,

Karel

-----Oorspronkelijk bericht-----
Van: Crawford, Lindy [mailto:[EMAIL PROTECTED]
Verzonden: woensdag 19 november 2003 14:43
Aan: [EMAIL PROTECTED]
Onderwerp: 3583 LTO Library


Hi TSMer's,

Please could you assist me, we have been have continuous errors on our
library above and have update all microcode and firmware, but still no joy-

I get the following error:-

11/19/2003 15:11:39   ANR8300E I/O error on library IBM3583 (OP=8401C058,

                       CC=304, KEY=04, ASC=15, ASCQ=83,
SENSE=70.00.04.00.00.00-
                       .00.0A.00.00.00.00.15.83.7C.00.00.00.,