Hello. Timely subject for me as I have just begun using LTO-2s and LTO-1s. I was a big DLT users for years, still am but not with Tivoli.
Note.. assuming of course, one must remember that if you are compressing the Tivoli backup data on disk, when it gets to tape, even if you are compressing on tape, the tape won't compress very much??? Then on this note, I am curious why when I defined my LTO-2 and LTO-1 tape types, I specified LTO2C and LTO1C which should compress up to 400 GIGs for an LTO2 and 200 GIGs for an LTO1. But my q vol shows 200 GIGs and 100 GIGs used at FULL. Anyone else see this or comment. Tks Charlie H Tecsys Inc. -----Original Message----- From: ADSM: Dist Stor Manager [mailto:[EMAIL PROTECTED] Behalf Of David Longo Sent: Thursday, January 22, 2004 11:56 AM To: [EMAIL PROTECTED] Subject: Re: Cartridge Estimated capacity Relatively simple. The "EST CAP" is set when you define the DEVCLASS, probably 80GB in this case (see line for tape 000034). When data is then writtent to the tape, the EST Cap is updated to the ACTUAL capacity when the tape gets FULL. This may be higher or lower than the value in the defioned devclass. The tape will show the original EST Cap while FILLING until the amount of data exceeds this value. Then it increases as data is added until tape is FULL. The tapes that show FULL but have a pct Util less than 100 are mostly tapes had some of the data expired since they became FULL. David B. Longo System Administrator Health First, Inc. 3300 Fiske Blvd. Rockledge, FL 32955-4305 PH 321.434.5536 Pager 321.634.8230 Fax: 321.434.5509 [EMAIL PROTECTED] >>> [EMAIL PROTECTED] 01/22/04 11:45AM >>> Hi to all Can anybody tell me why the huge difference between the numbers of Estimated Capacity of a full cartidge DLT8000 (40/80 G). The format of the devclass was configure to DRIVE. The nodes are backup without compression . Here the output of the q vol. Volume Name Storage Device Estimated Pct Volume Pool Name Class Name Capacity Util Status (MB) ------------------------ ----------- ---------- --------- ----- -------- 000002 SCA_UNIX SCALARCLA- 58,089.8 96.5 Full SS 000009 SCA_UNIX SCALARCLA- 165,222.0 64.6 Full SS 000016 SCA_UNIX SCALARCLA- 76,230.3 49.1 Full SS 000027 SCA_UNIX SCALARCLA- 65,272.7 40.9 Full SS 000034 SCA_UNIX SCALARCLA- 80,000.0 3.9 Filling SS 000044 SCA_UNIX SCALARCLA- 136,684.2 62.8 Full SS 000111 SCA_UNIX SCALARCLA- 48,768.3 44.5 Full SS 000141 SCA_UNIX SCALARCLA- 51,704.7 40.6 Full SS 000158 SCA_UNIX SCALARCLA- 70,574.6 97.3 Full SS 000159 SCA_UNIX SCALARCLA- 80,000.0 62.9 Filling T.I.A Regards Robert Ouzen E-mail: [EMAIL PROTECTED] ############################################################## This message is for the named person's use only. It may contain confidential, proprietary, or legally privileged information. No confidentiality or privilege is waived or lost by any mistransmission. If you receive this message in error, please immediately delete it and all copies of it from your system, destroy any hard copies of it, and notify the sender. You must not, directly or indirectly, use, disclose, distribute, print, or copy any part of this message if you are not the intended recipient. Health First reserves the right to monitor all e-mail communications through its networks. Any views or opinions expressed in this message are solely those of the individual sender, except (1) where the message states such views or opinions are on behalf of a particular entity; and (2) the sender is authorized by the entity to give such views or opinions. ##############################################################