Very likely, your library driver has not yet "discovered" the new column. For AIX I would delete the library device (e.g.: /dev/smc0) and run cfgmgr again to acquire the new "Vital Product Data".
Orville L. Lantto Datatrend Technologies, Inc. (http://www.datatrend.com) IBM Premier Business Partner 121 Cheshire Lane, Suite 700 Minnetonka, MN 55305 Email: [EMAIL PROTECTED] CONFIDENTIALITY NOTICE: This e-mail message, including any attachments, is for the sole use of the intended recipient(s) and may contain confidential and privileged information. Any unauthorized review, use, disclosure or distribution is prohibited. If you are not the intended recipient, please contact the sender by reply e-mail and destroy all copies of the original message. Frank Verhoeven <[EMAIL PROTECTED]> Sent by: "ADSM: Dist Stor Manager" <[EMAIL PROTECTED]> 06/01/2004 02:46 AM Please respond to "ADSM: Dist Stor Manager" To: [EMAIL PROTECTED] cc: Subject: Second storage column for the Ultrium 3583 I have installed a second storage column in our Ultrium 3583. On the display, the System Dialog screen from the library submenu is telling me that there are 18 empty slots left, but it's not possible to check in tapes. I get the message: ANR8314E Library LB1 is full. Have i forgotten something? Frank Verhoeven