You need to update your dsmserv.opt file and include a line that tells
TSM where to store device configuration information.

If you edit the dsmserv.opt file, you may find lots of commented-out
text in there explaining various options to you. There will be an
explanation of the option DEVCONFIG. This is the one you need to set.

If your dsmserv.opt does not contain the helpful text, then basicaly you
need to add a line to your dsmserv.opt that reads;

DEVCONFIG /a/path/and/filename

For example, for our TSM servers we use

    DEVCONFig /usr/tivoli/tsm/server/bin/devconf.out
    DEVCONFig /usr/tivoli/tsm/tsmdrm/devconf.out



Matt.


-----Original Message-----
From: ADSM: Dist Stor Manager [mailto:[EMAIL PROTECTED] On Behalf Of
Geetha Thanu
Sent: Tuesday, August 31, 2004 6:20 AM
To: [EMAIL PROTECTED]
Subject: unable to update device config file

Hi all,

when I was trying to add new cartridges I got the following error for
label
libvolume and checkin libvolume

ANR1434W No files have been identified for automatically
                       storing device configuration information.

I saw in the err messages pdf of IBM but unable to know what I have to
do correctly.

Please help.

Thanks

Geetha Thanu

-


___________________________ Disclaimer Notice __________________________
This message and any attachments are confidential and should only be read by those to 
whom they are addressed. If you are not the intended recipient, please contact us, 
delete the message from your computer and destroy any copies. Any distribution or 
copying without our prior permission is prohibited.

Internet communications are not always secure and therefore Powergen Retail Limited 
does not accept legal responsibility for this message. The recipient is responsible 
for verifying its authenticity before acting on the contents. Any views or opinions 
presented are solely those of the author and do not necessarily represent those of 
Powergen Retail Limited. 

Registered addresses:

Powergen Retail Limited, Westwood Way, Westwood Business Park, Coventry, CV4 8LG.
Registered in England and Wales No: 3407430

Telephone +44 (0) 2476 42 4000
Fax +44 (0) 2476 42 5432

Reply via email to