Interesting. This just reminded me of a question I keep meaning to ask; Can anyone get the -f option to work for tapeutil on anything other than AIX?
At this site the command returns with no output on either solaris / hpux at various code levels. It's annoying, because we have to go through the menu's when we are inq 83'ing drives to see WWN's, rather than being able to use a script. Matt. -------------------------- Matthew Warren. [EMAIL PROTECTED] [EMAIL PROTECTED] http://tsmwiki.com/tsmwiki/MatthewWarren -----Original Message----- From: ADSM: Dist Stor Manager [mailto:[EMAIL PROTECTED] On Behalf Of David Longo Sent: Thursday, July 28, 2005 2:29 PM To: [email protected] Subject: Re: tapeutil question ! tapeutil -f /dev/smc0 inventory > tapelist Standard unix i.o. David B. Longo System Administrator Health First, Inc. 3300 Fiske Blvd. Rockledge, FL 32955-4305 PH 321.434.5536 Pager 321.634.8230 Fax: 321.434.5509 [EMAIL PROTECTED] >>> [EMAIL PROTECTED] 07/28/05 7:28 AM >>> hi fellas ! just a quick one, how to redirect outpur from tapeutil to a file ? i would like to file element inventory, thanks ... goran vipnet problems following, if any want to take a look thanks ... ANR8457I AUDIT LIBRARY: Operation for library LTO_LIB03 started as process 9. ANR8300E I/O error on library LTO_LIB03 (OP=00006C03, CC=207, KEY=05, ASC=83, ASCQ=04, SENSE=70.00.05.00.00.00.00.0A.00.00.00.00.83.04.42.00.00.00., Description=Device is not in a state capable of performing request). Refer to Appendix D in the 'Messages' manual for recommended action. ANR8942E Could not move volume NOT KNOWN from slot-element 4096 to slot-element 261. ANR8460E AUDIT LIBRARY process for library LTO_LIB03 failed. ANR0985I Process 9 for AUDIT LIBRARY running in the BACKGROUND completed with completion state FAILURE at 11:07:18. ANR8470W Initialization failure on drive DRIVE04 in library LTO_LIB03. ANR8912E Unable to verify the label of volume from slot-element 16 in drive DRIVE04 (/dev/rmt4) in library LTO_LIB03. ANR8951I Device /dev/rmt4, volume unknown has issued the following Information TapeAlert: The tape in the drive is a cleaning cartridge. ANR8302E I/O error on drive DRIVE05 (/dev/rmt4) (OP=WRITE, Error Number=5, CC=0, KEY=0B, ASC=4B, ASCQ=00, SENSE=70.00.0B.00.00.00.00.0A.00.00.00.00.4B.00.00.00.00.00, Description=An undetermined error has occurred). Refer to Appendix D in the 'Messages' manual for recommended action. ANR1411W Access mode for volume 963AGG now set to "read-only" due to write error. IBM Tape Device Error Log Analysis A00000 NAME: rmt4 LOCATION: 20-58-0 DEVICE TYPE: 3580 DATE: 07/28/05 04:54:00 SEQUENCE #26232 ERROR ID: HARDWARE ERROR SCSI CDB: 0A0004000000 SCSI STATUS BYTE: CHECK CONDITION SENSE KEY: B ASC/ASCQ: 4B00 SCSI SENSE BYTES 0-17: 70000B000000000A000000004B0000000000 SCSI EXTENDED SENSE BYTES: 0000000000000000000000000000000000000000000000000000000000000000 000000000000000000000000000000000000000000000000000000000000 NAME: rmt4 LOCATION: 20-58-0 DEVICE TYPE: 3580 DATE: 07/28/05 04:53:31 SEQUENCE #26231 ERROR ID: HARDWARE ERROR SCSI CDB: 0A0004000000 SCSI STATUS BYTE: CHECK CONDITION SENSE KEY: B ASC/ASCQ: 4B00 SCSI SENSE BYTES 0-17: 70000B000000000A000000004B0000000000 SCSI EXTENDED SENSE BYTES: 0000000000000000000000000000000000000000000000000000000000000000 000000000000000000000000000000000000000000000000000000000000 Drive Address 256 Drive State .................... Abnormal ASC/ASCQ ....................... 8300 Media Present .................. Yes Robot Access Allowed ........... No Source Element Address Valid ... No Media Inverted ................. No Same Bus as Medium Changer ..... Yes SCSI Bus Address ............... 0 Logical Unit Number Valid ...... No Volume Tag ................. +----------------+ | | | 261 drive 3 | +----------------+ | | | 260 drive 2 | +----------------+ | | | 259 drive 6 | +----------------+ | | | 258 drive 5 | +----------------+ | | | 257 drive 1 | +----------------+ | | | 256 drive 4 | +----------------+ is DRIVE04 faulty ? ############################################################## This message is for the named person's use only. It may contain confidential, proprietary, or legally privileged information. No confidentiality or privilege is waived or lost by any mistransmission. If you receive this message in error, please immediately delete it and all copies of it from your system, destroy any hard copies of it, and notify the sender. You must not, directly or indirectly, use, disclose, distribute, print, or copy any part of this message if you are not the intended recipient. Health First reserves the right to monitor all e-mail communications through its networks. Any views or opinions expressed in this message are solely those of the individual sender, except (1) where the message states such views or opinions are on behalf of a particular entity; and (2) the sender is authorized by the entity to give such views or opinions. ############################################################## ___________________________ Disclaimer Notice __________________________ This message and any attachments are confidential and should only be read by those to whom they are addressed. If you are not the intended recipient, please contact us, delete the message from your computer and destroy any copies. Any distribution or copying without our prior permission is prohibited. Internet communications are not always secure and therefore Powergen Retail Limited does not accept legal responsibility for this message. The recipient is responsible for verifying its authenticity before acting on the contents. Any views or opinions presented are solely those of the author and do not necessarily represent those of Powergen Retail Limited. Powergen Retail Ltd is authorised and regulated by the Financial Services Authority for the sale and service of general insurance products. Registered addresses: Powergen Retail Limited, Westwood Way, Westwood Business Park, Coventry, CV4 8LG. Registered in England and Wales No: 3407430 Telephone +44 (0) 2476 42 4000 Fax +44 (0) 2476 42 5432