In this case, I don't see any issue with the quotes (or lack thereof). options=-domain=-systemobject is valid.
My guess is that this occurs on a system that does not support the SYSTEMOBJECT domain, such as Windows 2003. Regards, Andy Andy Raibeck IBM Software Group Tivoli Storage Manager Client Product Development Level 3 Team Lead Internal Notes e-mail: Andrew Raibeck/Tucson/[EMAIL PROTECTED] Internet e-mail: [EMAIL PROTECTED] IBM Tivoli Storage Manager support web page: http://www.ibm.com/software/sysmgmt/products/support/IBMTivoliStorageManager.html The only dumb question is the one that goes unasked. The command line is your friend. "Good enough" is the enemy of excellence. "ADSM: Dist Stor Manager" <[email protected]> wrote on 10/19/2007 09:55:41 AM: > Have you done a q sched f=d to see how it displays? Does it display with the > double quotes? > I know I have run into this situation doing a def/update sched on AIX > > ----- Original Message ----- > From: "Tim Brown" <[EMAIL PROTECTED]> > To: <[email protected]> > Sent: Friday, October 19, 2007 12:50 PM > Subject: Re: [ADSM-L] schedule to exclude system object > > > > Have tried various combinations no luck > > > > Tim > > > > ----- Original Message ----- > > From: "Larry Clark" <[EMAIL PROTECTED]> > > To: <[email protected]> > > Sent: Friday, October 19, 2007 11:45 AM > > Subject: Re: schedule to exclude system object > > > > > >> looks like you have a problem with the quotes. It is inserted with single > >> ticks insrtead of quotes. Just a guess. do a q sched f=d to verify. > >> > >> If so you may have to do something like: > >> > >> update schedule nt nt_daily_fs option='"-domain=-systemobject'" > >> > >> single tick then quote to preserve the double quote. > >> > >> > >> should be "-domain=sys > >> ----- Original Message ----- > >> From: "Tim Brown" <[EMAIL PROTECTED]> > >> To: <[email protected]> > >> Sent: Friday, October 19, 2007 11:33 AM > >> Subject: [ADSM-L] schedule to exclude system object > >> > >> > >> Created schedule to exclude system object as described in client admin > >> for > >> windows guide > >> > >> update schedule nt nt_daily_fs option="-domain=-systemobject" > >> > >> This is exactly how its coded in the manual > >> > >> However when client schedule runs I get this error > >> > >> ANS1107E Invalid option/value: '-domain=-systemobject' > >> > >> > >> Tim Brown > >> Systems Specialist - Project Leader > >> Central Hudson Gas & Electric > >> 284 South Ave > >> Poughkeepsie, NY 12601 > >> Email: [EMAIL PROTECTED] > >> Phone: 845-486-5643 > >> Fax: 845-486-5921 > >> Cell: 845-235-4255 > >>