Hi,

this is perhaps a newbee question, but:

how do i check new tapes into a 3584 library using the I/O-station?

what i want to do:
i'm running two tape libraries, and because the year ends soon, some
money has left for buying new tapes to fill both library.

unfortunately a certain time ago some tapes belonging (due to their
labeling) to library B have been inserted into library A.

now i remove this tapes from A and want to replace them by the new ones.
well, in library A there are only a few scratch tapes, so I cannot empty
all the wrong tapes and remove them all at once.
instead I empty just 10 of them and then remove them by checking out to
the I/O-station.
actually I want to check-in and label the right-labeled inserted in the
I/O-station.

what i already tried:

dsm> checkin libvolume 3584 search=yes checkin=scratch

dsm> label libv 3584 search=yes labels=barcode checkin=scratch
volrange=ABW500,ABW509

dsm> label libv 3584 search=bulk labels=barcode checkin=scratch
volrange=ABW500,ABW509

thanks

Bjørn

-- 
########################################################################