We have the same library as you, are the label prefixes different on the media types and have you set a cartridge assignment policy which means that the library won't take the media into the logical library without being told what the sequence of labels are???
Just a thought? -----Original Message----- From: ADSM: Dist Stor Manager [mailto:[email protected]] On Behalf Of Rodney Luk Sent: 27 October 2010 01:15 To: [email protected] Subject: [ADSM-L] Mixed LTO3 and LTO5 tape drives We replaced 4 LTO3 tape drives with new LTO5 drives in our 3584 library. The library has 4 LTO3 and 4 LTO5 tape drives now. A new device class has created for the LTO5 drives. A new primary storage pool has created and bind to the new LTO5 device class. I am able to migrate the data from the disk pools to the new LTO5 storage pool but I couldn't move data from the LTO3 primary tape storage pool to the new LTO5 tape storage. The TSM server is at 5.5.4.0 on a Windows Server 2003 machine. The tape driver has update to the latest version 6212. I have recreated all the drives and paths. Appreciated for any help, Rodney Below is the activity logs 10/26/2010 3:28:23 PM ANR1420W Read access denied for volume T00008L5 - volume access mode = "unavailable". 10/26/2010 3:28:23 PM ANR0565W Retrieve or restore failed for session 17470 for node Sever01 (WinNT). The storage volume T00008L5 is inaccessible. 10/26/2010 4:37:38 PM ANR1258W Files on volume A01504L3 needed for move data cannot be accessed - access mode is "unavailable", "offsite", or "destroyed". 10/26/2010 4:40:59 PM ANR8311E An I/O error occurred while accessing drive MT1.0.0.7 (\\.\Tape6) for GET_TAPE_DRIVE_INFORMATION operation, errno = 121, rc = 1. 10/26/2010 4:41:03 PM ANR8311E An I/O error occurred while accessing drive MT0.0.0.7 (\\.\Tape7) for GET_TAPE_DRIVE_INFORMATION operation, errno = 121, rc = 1. 10/26/2010 4:41:18 PM ANR1401W Mount request denied for volume A01141L3 - mount failed. 10/26/2010 4:41:21 PM ANR1404W Scratch volume mount request denied - mount failed. 10/26/2010 4:41:21 PM ANR8300E I/O error on library LB0.1.0.4 (OP=8401C058, CC=314, KEY=FF, ASC=FF, ASCQ=FF,~SENSE=**NONE**,~Description=The source slot or drive was empty in an attempt to move a volume). Refer to Appendix C in the 'Messages' manual for recommended action. 10/26/2010 4:41:21 PM ANR8312E Volume T00008L5 could not be located in library LB0.1.0.4. 10/26/2010 4:41:21 PM ANR8358E Audit operation is required for library LB0.1.0.4. 10/26/2010 4:41:21 PM ANR8381E LTO volume T00008L5 could not be mounted in drive MT1.0.0.6 (\\.\Tape5). 10/26/2010 4:41:21 PM ANR1402W Mount request denied for volume T00008L5 - volume unavailable. 10/26/2010 4:41:21 PM ANR1410W Access mode for volume T00008L5 now set to "unavailable". 10/26/2010 4:44:37 PM ANR8311E An I/O error occurred while accessing drive MT0.0.0.7 (\\.\Tape7) for GET_TAPE_DRIVE_INFORMATION operation, errno = 121, rc = 1. 10/26/2010 4:45:08 PM ANR1404W Scratch volume mount request denied - mount failed. 10/26/2010 4:48:25 PM ANR8311E An I/O error occurred while accessing drive MT1.0.0.7 (\\.\Tape6) for GET_TAPE_DRIVE_INFORMATION operation, errno = 121, rc = 1. 10/26/2010 4:48:43 PM ANR1404W Scratch volume mount request denied - mount failed. 10/26/2010 4:52:02 PM ANR8311E An I/O error occurred while accessing drive MT0.0.0.7 (\\.\Tape7) for GET_TAPE_DRIVE_INFORMATION operation, errno = 121, rc = 1. 10/26/2010 4:52:20 PM ANR1401W Mount request denied for volume A01716L3 - mount failed. 10/26/2010 4:52:20 PM ANR1144W Move data process terminated for volume A01716L3 - storage media inaccessible. Below is the information about the drives and path 5:05:33 PM SERVER01 : q drive f=d Library Name: LB0.1.0.4 Drive Name: MT0.0.0.3 Device Type: LTO On-Line: Yes Read Formats: ULTRIUM3C,ULTRIUM3,ULTRIUM2C,ULT- RIUM2,ULTRIUMC,ULTRIUM Write Formats: ULTRIUM3C,ULTRIUM3,ULTRIUM2C,ULT- RIUM2 Element: 257 Drive State: EMPTY Volume Name: Allocated to: WWN: Serial Number: 1210011646 Last Update by (administrator): USER Last Update Date/Time: 10/25/2010 10:00:11 Cleaning Frequency (Gigabytes/ASNEEDED/NONE): NONE Library Name: LB0.1.0.4 Drive Name: MT0.0.0.4 Device Type: LTO On-Line: Yes Read Formats: ULTRIUM3C,ULTRIUM3,ULTRIUM2C,ULT- RIUM2,ULTRIUMC,ULTRIUM Write Formats: ULTRIUM3C,ULTRIUM3,ULTRIUM2C,ULT- RIUM2 Element: 258 Drive State: EMPTY Volume Name: Allocated to: WWN: 500507630F040302 Serial Number: 1210011620 Last Update by (administrator): USER Last Update Date/Time: 10/25/2010 10:00:09 Cleaning Frequency (Gigabytes/ASNEEDED/NONE): NONE Library Name: LB0.1.0.4 Drive Name: MT0.0.0.6 Device Type: LTO On-Line: Yes Read Formats: ULTRIUM5C,ULTRIUM5,ULTRIUM4C,ULT- RIUM4,ULTRIUM3C,ULTRIUM3 Write Formats: ULTRIUM5C,ULTRIUM5,ULTRIUM4C,ULT- RIUM4 Element: 264 Drive State: LOADED Volume Name: T00001L5 Allocated to: SERVER01 WWN: 500507630F040308 Serial Number: 00078A05D8 Last Update by (administrator): USER Last Update Date/Time: 10/25/2010 10:00:06 Cleaning Frequency (Gigabytes/ASNEEDED/NONE): NONE Library Name: LB0.1.0.4 Drive Name: MT0.0.0.7 Device Type: LTO On-Line: Yes Read Formats: ULTRIUM5C,ULTRIUM5,ULTRIUM4C,ULT- RIUM4,ULTRIUM3C,ULTRIUM3 Write Formats: ULTRIUM5C,ULTRIUM5,ULTRIUM4C,ULT- RIUM4 Element: 261 Drive State: EMPTY Volume Name: Allocated to: WWN: 500507630F040305 Serial Number: 00078A05EE Last Update by (administrator): USER Last Update Date/Time: 10/24/2010 14:10:13 Cleaning Frequency (Gigabytes/ASNEEDED/NONE): NONE Library Name: LB0.1.0.4 Drive Name: MT1.0.0.3 Device Type: LTO On-Line: Yes Read Formats: ULTRIUM3C,ULTRIUM3,ULTRIUM2C,ULT- RIUM2,ULTRIUMC,ULTRIUM Write Formats: ULTRIUM3C,ULTRIUM3,ULTRIUM2C,ULT- RIUM2 Element: 259 Drive State: EMPTY Volume Name: Allocated to: WWN: Serial Number: 0007841809 Last Update by (administrator): USER Last Update Date/Time: 10/25/2010 10:00:03 Cleaning Frequency (Gigabytes/ASNEEDED/NONE): NONE Library Name: LB0.1.0.4 Drive Name: MT1.0.0.4 Device Type: LTO On-Line: Yes Read Formats: ULTRIUM3C,ULTRIUM3,ULTRIUM2C,ULT- RIUM2,ULTRIUMC,ULTRIUM Write Formats: ULTRIUM3C,ULTRIUM3,ULTRIUM2C,ULT- RIUM2 Element: 260 Drive State: EMPTY Volume Name: Allocated to: WWN: 500507630F040304 Serial Number: 0007841822 Last Update by (administrator): USER Last Update Date/Time: 10/24/2010 14:10:05 Cleaning Frequency (Gigabytes/ASNEEDED/NONE): NONE Library Name: LB0.1.0.4 Drive Name: MT1.0.0.6 Device Type: LTO On-Line: Yes Read Formats: ULTRIUM5C,ULTRIUM5,ULTRIUM4C,ULT- RIUM4,ULTRIUM3C,ULTRIUM3 Write Formats: ULTRIUM5C,ULTRIUM5,ULTRIUM4C,ULT- RIUM4 Element: 263 Drive State: EMPTY Volume Name: Allocated to: WWN: 500507630F040307 Serial Number: 00078A05C2 Last Update by (administrator): USER Last Update Date/Time: 10/25/2010 10:00:00 Cleaning Frequency (Gigabytes/ASNEEDED/NONE): NONE Library Name: LB0.1.0.4 Drive Name: MT1.0.0.7 Device Type: LTO On-Line: Yes Read Formats: ULTRIUM5C,ULTRIUM5,ULTRIUM4C,ULT- RIUM4,ULTRIUM3C,ULTRIUM3 Write Formats: ULTRIUM5C,ULTRIUM5,ULTRIUM4C,ULT- RIUM4 Element: 262 Drive State: EMPTY Volume Name: Allocated to: WWN: 500507630F040306 Serial Number: 00078A05E3 Last Update by (administrator): USER Last Update Date/Time: 10/22/2010 17:03:27 Cleaning Frequency (Gigabytes/ASNEEDED/NONE): NONE 5:05:45 PM SERVER01 : q path f=d Source Name: SERVER01 Source Type: SERVER Destination Name: LB0.1.0.4 Destination Type: LIBRARY Library: Node Name: Device: lb0.1.0.3 External Manager: LUN: Initiator: 0 Directory: On-Line: Yes Last Update by (administrator): USER Last Update Date/Time: 10/20/2010 15:51:43 Source Name: SERVER01 Source Type: SERVER Destination Name: MT0.0.0.3 Destination Type: DRIVE Library: LB0.1.0.4 Node Name: Device: \\.\Tape0 External Manager: LUN: Initiator: 0 Directory: On-Line: Yes Last Update by (administrator): USER Last Update Date/Time: 10/25/2010 10:00:24 Source Name: SERVER01 Source Type: SERVER Destination Name: MT0.0.0.4 Destination Type: DRIVE Library: LB0.1.0.4 Node Name: Device: \\.\Tape1 External Manager: LUN: Initiator: 0 Directory: On-Line: Yes Last Update by (administrator): USER Last Update Date/Time: 10/25/2010 10:00:47 Source Name: SERVER01 Source Type: SERVER Destination Name: MT0.0.0.6 Destination Type: DRIVE Library: LB0.1.0.4 Node Name: Device: \\.\Tape4 External Manager: LUN: Initiator: 0 Directory: On-Line: Yes Last Update by (administrator): USER Last Update Date/Time: 10/25/2010 10:00:51 Source Name: SERVER01 Source Type: SERVER Destination Name: MT0.0.0.7 Destination Type: DRIVE Library: LB0.1.0.4 Node Name: Device: \\.\Tape7 External Manager: LUN: Initiator: 0 Directory: On-Line: Yes Last Update by (administrator): SERVER01 Last Update Date/Time: 10/24/2010 19:58:44 Source Name: SERVER01 Source Type: SERVER Destination Name: MT1.0.0.3 Destination Type: DRIVE Library: LB0.1.0.4 Node Name: Device: \\.\Tape2 External Manager: LUN: Initiator: 0 Directory: On-Line: Yes Last Update by (administrator): USER Last Update Date/Time: 10/25/2010 10:00:56 Source Name: SERVER01 Source Type: SERVER Destination Name: MT1.0.0.4 Destination Type: DRIVE Library: LB0.1.0.4 Node Name: Device: \\.\Tape3 External Manager: LUN: Initiator: 0 Directory: On-Line: Yes Last Update by (administrator): SERVER01 Last Update Date/Time: 10/24/2010 19:58:47 Source Name: SERVER01 Source Type: SERVER Destination Name: MT1.0.0.6 Destination Type: DRIVE Library: LB0.1.0.4 Node Name: Device: \\.\Tape5 External Manager: LUN: Initiator: 0 Directory: On-Line: Yes Last Update by (administrator): USER Last Update Date/Time: 10/25/2010 10:01:01 Source Name: SERVER01 Source Type: SERVER Destination Name: MT1.0.0.7 Destination Type: DRIVE Library: LB0.1.0.4 Node Name: Device: \\.\Tape6 External Manager: LUN: Initiator: 0 Directory: On-Line: Yes Last Update by (administrator): SERVER01 Last Update Date/Time: 10/24/2010 19:58:51 ________________________________ Confidentiality Notice: This e-mail message, including any attachments, is for the sole use of the intended recipient(s) and may contain confidential and privileged information. Any unauthorized review, use, disclosure or distribution is prohibited. If you are not the intended recipient, please contact the sender by reply e-mail and destroy all copies of the original message. Please check that this email is addressed to you. If not, you should delete it immediately as its contents may be confidential and its disclosure, copying or distribution unlawful. C. & J. Clark International Limited takes steps to prevent the transmission of electronic viruses but responsibility for screening incoming messages and the risk of such transmission lies with the recipient. C. & J. Clark International Limited Trading as Clarks, Registered in England number 141015.Registered office 40 High Street, Street, Somerset. BA16 0EQ. England. This message has been scanned for viruses by MailControl - www.MailControl.com