I am using format=drive in my devclass, no problem reading E05 tapes. A filling E05 tape will be written in E05 format, a new one in E06 format. But how to see which tape is written in E05 ? ( the written capacity is some hint, but on filling its difficult).

Am 11/5/10 2:51 PM, schrieb Richard Sims:
Would not your prior use of 3592-E05 have been with devclass Format 3592-2, and 
new use of 3592-E06 be with devclass Format 3592-3, in a recent TSM 
version/level supporting that specification?

     Richard Sims


--
--
Matthias Feyerabend                                | [email protected]
GSI Helmholtzzentrum für Schwerionenforschung GmbH | phone +49-6159-71-2519
Planckstr. 1                                       | privat +49-6151-718781
D-64291 Darmstadt                                  | fax   +49-6159-71-2519
www.gsi.de
Gesellschaft mit beschränkter Haftung
Sitz der Gesellschaft: Darmstadt
Handelsregister: Amtsgericht Darmstadt, HRB 1528

Geschäftsführung: Professor Dr. Dr. h.c. Horst Stöcker,
Dr. Hartmut Eickhoff

Vorsitzende des Aufsichtsrates: Dr. Beatrix Vierkorn-Rudolph
Stellvertreter: Ministerialdirigent Dr. Rolf Bernhardt

Reply via email to