We have been using node replication for a couple years now with out a problem on 6.3.x. We only replicate active data. Two weeks ago we upgraded our destination system to 7.1.1.100 and last week one of our source systems. That was Tuesday. Thursday/Friday all of the TDP for SQL nodes started sending full backups where the occupancy on each side is the same except we have a 7 day retention on the source. To my knowledge: nothing was changed later in the week, everything is set to replicate active data only, only the TDP nodes seem to be impacted. Any ideas? I have opened a ticket but IBM's slow to respond...
source config <truncated>: q status Default Replication Rule for Archive: ALL_DATA Default Replication Rule for Backup: ACTIVE_DATA Default Replication Rule for Space Management: ALL_DATA tsm: TSMPRD02>q copy tdpsql f=d Policy Domain Name: TDPSQL Policy Set Name: ACTIVE Mgmt Class Name: TDPSQL_MC Copy Group Name: STANDARD Copy Group Type: Backup Versions Data Exists: No Limit Versions Data Deleted: No Limit Retain Extra Versions: 7 Retain Only Version: 7 Copy Mode: Modified Copy Serialization: Shared Dynamic Copy Frequency: 0 Copy Destination: FP01 Table of Contents (TOC) Destination: Last Update by (administrator): ADMIN Last Update Date/Time: 12/24/1309:36:43 Managing profile: Changes Pending: No q node <sample node> Backup Replication Rule: DEFAULT Archive Replication Rule: DEFAULT Space Management Replication Rule: DEFAULT q file <sample node> Backup Replication Rule Name: DEFAULT Backup Replication Rule State: Enabled Archive Replication Rule Name: DEFAULT Archive Replication Rule State: Enabled Space Management Replication Rule Name: DEFAULT Space Management Replication Rule State: Enabled --------------------------------------------------- David Nixon System Programmer II, Enterprise Storage Team Carilion Clinic | 451 Kimball Avenue | Roanoke, VA 24016 540.224.3903 (Work) 540.525.8000 (Mobile) ________________________________ Notice: The information and attachment(s) contained in this communication are intended for the addressee only, and may be confidential and/or legally privileged. If you have received this communication in error, please contact the sender immediately, and delete this communication from any computer or network system. Any interception, review, printing, copying, re-transmission, dissemination, or other use of, or taking of any action upon this information by persons or entities other than the intended recipient is strictly prohibited by law and may subject them to criminal or civil liability. Carilion Clinic shall not be liable for the improper and/or incomplete transmission of the information contained in this communication or for any delay in its receipt.