That would be an AP though - those will run on pretty much any 48v PoE you
throw at it. The 900mhz 450i SMs do need to have the old Canopy PoE pinout.

On Mon, Aug 6, 2018 at 9:38 AM Mike Davis <wispali...@allianceinternet.net>
wrote:

> We have a Cambium 450i 900 powered by a Netonix WS-12-250-DC ("48V"
> setting). Works fine. Check the Netonix forum for a list of equipment
> verified that can be powered by a Netonix:
>
> https://forum.netonix.com/viewtopic.php?f=6&t=1215
> Mike Davis
>
> On 8/2/2018 8:22 AM, Christopher Gray wrote:
>
> Thank you... I was hoping they started doing both like the ePMP line. It
> would sure make it easier to transition to Cambium gear.
>
> I have plenty of switched pairs, but they will eventually lead to fried
> gear somewhere (when someone makes the mistake of plugging in the wrong
> wire).
>
>
> ------------------------------
>
>
> On Thu, Aug 2, 2018 at 12:15 AM Mathew Howard <mhoward...@gmail.com>
> wrote:
>
>> No, they will not. They need to have negative on pins 4&5 and positive on
>> 7&8. It'll work fine if you just swap those two pairs in one end of the
>> cable.
>>
>> On Wed, Aug 1, 2018 at 10:23 PM Christopher Gray <
>> cg...@graytechsoftware.com> wrote:
>>
>>> Will the PMP 450i 900 MHz SM work with standard polarity? I understand
>>> they work with Cambium polarity from 20-32V, but I want to run one off a
>>> Netonix, and I'm not sure whether I need to reverse polarity or not.
>>>
>>> Thank you - Chris
>>> --
>>> AF mailing list
>>> AF@af.afmug.com
>>> http://af.afmug.com/mailman/listinfo/af_af.afmug.com
>>>
>> --
>> AF mailing list
>> AF@af.afmug.com
>> http://af.afmug.com/mailman/listinfo/af_af.afmug.com
>>
>
>
>
> --
> AF mailing list
> AF@af.afmug.com
> http://af.afmug.com/mailman/listinfo/af_af.afmug.com
>
-- 
AF mailing list
AF@af.afmug.com
http://af.afmug.com/mailman/listinfo/af_af.afmug.com

Reply via email to