But is the Adtran feeding it a 1PPS source or also a time/date stamp?
That would be worth reaching out to RAD about, especially considering
the timing.
<https://atheral.com/>
Daniel White
Co-Founder - Business Development & Operations
direct: +1 (702) 470-2766
Facebook icon <https://www.facebook.com/getatheral> LinkedIn icon
<https://www.linkedin.com/company/atheral/> Youtbue icon
<https://www.youtube.com/channel/UCpPZv-EsGCj8LXfzylwCrjQ>
Matt Hoppes wrote on 4/10/19 21:04:
Timing source is an Adtran that’s doing fine with other T1s.
On Apr 10, 2019, at 23:59, Carl Peterson <[email protected]> wrote:
I'm guessing it has a timing source and doesn't like rollover
On Apr 10, 2019, at 9:02 PM, Matt Hoppes <[email protected]>
wrote:
Anyone here experienced with the RADMUX IP-24?
I have a pair that's been working fine to transport a T1 line over our IP
network for months.
A few days ago it just started flapping up and down, and is now down with:
Connectivity status: > (UNAVAILABLE )
We've verified no packet loss on either side, stable ping times, and that both
units can ping and traceroute to the other.
I'm at a loss for what else to try or what might have broken.
--