Try going direct dc to the unit.

roland

-----Original Message-----
From: AF <af-boun...@af.afmug.com> On Behalf Of Caleb Knauer
Sent: Thursday, November 12, 2020 10:02 AM
To: AnimalFarm Microwave Users Group <af@af.afmug.com>
Subject: Re: [AFMUG] looking for replacement 11 GHz 820C radio

Yeah my bad on that, not enough coffee.  They are not showing stock for the 
original one, but they are for the 27 non-mimo unit.  ISP Supplies shows the 27 
also.  WAV shows 15 in stock of the 27 too.

On Thu, Nov 12, 2020 at 9:59 AM Ken Hohhof <af...@kwisp.com> wrote:
>
> Oops, so they are not showing stock?
>
> If I'm seeing correctly, Streakwave has qty=1 in stock, not sure if that's 
> Ohio or Utah.  If they have one I can't drive and get it at will call like I 
> would from WAV, but I could overnight it in.
>
> I don't have a Winncomm account, not sure I can check stock status online.
>
>
> -----Original Message-----
> From: AF <af-boun...@af.afmug.com> On Behalf Of Caleb Knauer
> Sent: Thursday, November 12, 2020 8:40 AM
> To: AnimalFarm Microwave Users Group <af@af.afmug.com>
> Subject: Re: [AFMUG] looking for replacement 11 GHz 820C radio
>
> Wait no I'm blind.
>
> On Thu, Nov 12, 2020 at 9:38 AM Caleb Knauer <cknauer.li...@gmail.com> wrote:
> >
> > Winncomm site says they have 9 in stock.
> >
> > On Thu, Nov 12, 2020 at 9:36 AM Ken Hohhof <af...@kwisp.com> wrote:
> > >
> > > Anyone have a spare Cambium P/N C110082B055A on the shelf?  That’s an 11 
> > > GHz 820C and I believe it’s the high side.  I’m trying the distributors 
> > > but I think people have posted here about 820C supply problems lately so 
> > > I’m not optimistic.
> > >
> > >
> > >
> > > Really strange, we had a power outage and the radio seems stuck in a boot 
> > > loop and won’t power up.  It was fine for 2 years before the power went 
> > > off.  Cambium Support is wanting me to try logging in via a “protection 
> > > cable” but I doubt that will work, it’s not that we lost the IP address, 
> > > the radio seems to be rebooting every 45 seconds or so.  If I power it 
> > > from one of the Cambium outdoor POEs (the ones that take 24 or 48 VDC 
> > > in), the POE light actually goes orange periodically for a few seconds.  
> > > I had hoped it was a POE or power supply problem, but replacing them 
> > > didn’t fix it.
> > >
> > > --
> > > AF mailing list
> > > AF@af.afmug.com
> > > http://af.afmug.com/mailman/listinfo/af_af.afmug.com
>
> --
> AF mailing list
> AF@af.afmug.com
> http://af.afmug.com/mailman/listinfo/af_af.afmug.com
>
>
>
> --
> AF mailing list
> AF@af.afmug.com
> http://af.afmug.com/mailman/listinfo/af_af.afmug.com

--
AF mailing list
AF@af.afmug.com
http://af.afmug.com/mailman/listinfo/af_af.afmug.com


-- 
AF mailing list
AF@af.afmug.com
http://af.afmug.com/mailman/listinfo/af_af.afmug.com

Reply via email to