I've put up alot of the F300, haven't seen any problems. Bad cable or
Radio? Did you try a different POE? 9/10 times Ethernet seems to be a
problem with the termination and/or cable. I've done 1000's of ends,
but just the other day I did one with one blue and green wire switched,
I think that caused weird Ethernet problems. Of course it was the end
at the radio and not the easy-to-get-to inside connection.
On 7/15/2021 9:32 PM, Jaime Solorza wrote:
Installed a PTP link with great signal but Ethernet port will not
lock at 1000FDX...only 100FDx...if i force it it loses connection or
10mbps hex...
Latest firmware...
Any ideas?
I even put a Trendnet Ethernet switch between Poe and Edgeswitch...
Thanks
--
AF mailing list
[email protected]
http://af.afmug.com/mailman/listinfo/af_af.afmug.com