I guess both indoor and outdoor?  Bonding for R56 compliance and also for maybe getting RF noise to ground without going through our switch.

I suppose indoor we can hack it, and outdoor might as well use the surge suppressor.  I'd imagine the housing and glands and such is more money than the PCB so there's nothing gained by paring it down.

-Adam



On 10/7/2021 12:56 PM, Chuck McCown via AF wrote:
Trim back the jacket and attach a ground wire.  Are you wanting something for outdoor mounting?  It would have to be two shielded jacks and you would have to use shielded plugs on it.  So two jacks on a pcb and then some kind of housing.

-----Original Message----- From: Adam Moffett
Sent: Thursday, October 7, 2021 10:45 AM
To: AnimalFarm Microwave Users Group
Subject: [AFMUG] Ethernet ground block

Is there an equivalent to the cable TV ground blocks but for Cat5?

I would basically look like a coupler with a ground wire attached to the
shield.  Much more basic than a surge suppressor.

-Adam




--
AF mailing list
[email protected]
http://af.afmug.com/mailman/listinfo/af_af.afmug.com

Reply via email to